PXe-M series Single Phase Input to Three Phase Output Static Frequency Converters
PXe-130000-M Series
PX Electronics PXe-130000-M Series Static Frequency Converters provide a stable, balanced three-phase AC output where only a single-phase power supply is available. The range combines phase, voltage and frequency conversion within one solid-state system, allowing compatible three-phase machinery and electrical equipment to operate without a direct three-phase utility connection.
Typical configurations convert 110V, 115V,120V, 220V, 230V or 240V single-phase input into a regulated three-phase output at 50Hz or 60Hz. Output voltage can be matched to the connected equipment, including common 200V, 208V, 220V, 380V, 400V, 415V, 440V, 460V and 480V three-phase systems.
Technical Highlights for Single-Phase to Three-Phase Frequency Conversion
Three-Phase Power from a Single-Phase Supply
Provides a regulated three-phase AC output where a three-phase utility supply is unavailable, impractical or costly to install.
Phase, Voltage & Frequency Conversion
Converts the incoming single-phase supply to a balanced three-phase output while also matching the voltage and frequency required by the connected equipment.
Balanced Three-Phase Output for Complete Equipment
Actively generates all three output phases with controlled phase separation and stable sine-wave output, making the PXe-M Series suitable for complete machines that contain motors, transformers, heaters, control circuits, and electronic power supplies.
Line voltage drop compensation
Compensates for voltage losses between the converter and connected three-phase equipment, helping maintain the required output voltage at the load despite cable length and operating current.
IGBT PWM Conversion with Transformer Isolation
Solid-state AC-DC-AC conversion provides controlled output voltage and frequency, while integrated transformer isolation provides electrical separation between the incoming single-phase supply and the connected three-phase load.
Input Assessment, Monitoring & Protection
Converter selection considers the available single-phase supply, protective devices, cable capacity and load starting demand. Front-panel metering provides voltage, current, frequency and system status, with remote communication and additional monitoring options available.
Product Information
PXe-M Series System Configuration
PXe-M Series Static Frequency Converters provide a regulated three-phase AC supply where only a single-phase electrical supply is available. The converters can also change the output voltage and frequency to suit the connected equipment.
Standard configurations cover 1kVA, 3kVA, 6kVA, 10kVA, 15kVA, 20kVA, 30kVA and 45kVA. Output arrangements can be specified as three-phase three-wire or three-phase four-wire with neutral.
Typical applications include 50Hz to 60Hz and 60Hz to 50Hz conversion for industrial machinery, laboratory equipment, production testing and equipment imported from different electrical markets. Selected 400Hz and specialist frequency configurations can also be considered following technical review.
Solid-state IGBT PWM conversion provides a regulated sine-wave output with integrated transformer isolation. Front-panel monitoring and protection functions are provided, with additional communication and remote-control arrangements available according to the selected configuration.
Converter selection must account for the available single-phase supply capacity, input protection, output current, load power factor and starting or transient demand. Larger converters require a suitably rated dedicated single-phase supply.
Popular Configurations
The following examples use a 230V single-phase, 50Hz input and a 230V line-to-neutral / 400V line-to-line, three-phase, 60Hz output. Alternative voltages, frequencies and neutral arrangements can be specified according to the application.
| MODEL | CAPACITY | INPUT | OUTPUT |
|---|---|---|---|
| PXe-130001-M | 1kVA | 230V ±10% 50Hz Single Phase |
230V L-N / 400V L-L 60Hz Three Phase + N |
| PXe-130003-M | 3kVA | 230V ±10% 50Hz Single Phase |
230V L-N / 400V L-L 60Hz Three Phase + N |
| PXe-130006-M | 6kVA | 230V ±10% 50Hz Single Phase |
230V L-N / 400V L-L 60Hz Three Phase + N |
| PXe-130010-M | 10kVA | 230V ±10% 50Hz Single Phase |
230V L-N / 400V L-L 60Hz Three Phase + N |
| PXe-130015-M | 15kVA | 230V ±10% 50Hz Single Phase |
230V L-N / 400V L-L 60Hz Three Phase + N |
| PXe-130020-M | 20kVA | 230V ±10% 50Hz Single Phase |
230V L-N / 400V L-L 60Hz Three Phase + N |
| PXe-130030-M | 30kVA | 230V ±10% 50Hz Single Phase |
230V L-N / 400V L-L 60Hz Three Phase + N |
| PXe-130045-M | 45kVA | 230V ±10% 50Hz Single Phase |
230V L-N / 400V L-L 60Hz Three Phase + N |
Configuration note: The configurations above are illustrative rather than fixed model specifications. Final input and output ratings, continuous current capability, load starting requirements and protection arrangements are confirmed for each application.
Output Phase and Neutral Arrangements
The PXe-M Series generates a three-phase output from the available single-phase supply. Output voltage and frequency can be selected to suit the connected equipment, with three-wire or four-wire arrangements available where required.
Where line-to-neutral loads are connected, the required neutral provision, expected phase imbalance, neutral current and earthing arrangement must be established. The final output transformer and protection configuration will reflect these requirements.
Input Supply and Load Assessment
Increasing the output voltage or generating three-phase power does not increase the power available from the single-phase input supply. Converter selection must account for the available input current, power factor, conversion losses, upstream protective devices and connected load.
Motor-driven equipment, compressors, transformers and other high-inrush loads require assessment of starting current and duration as well as the continuous operating rating. Larger M-Series units normally require a dedicated high-current single-phase electrical connection.
Installation and Enclosure Configurations
Compact and rack-mounted construction can be provided for suitable smaller models. Larger converters are normally supplied in floor-standing enclosures, with handling and mounting arrangements selected according to their weight, cooling requirements and installation.
IP20 is the standard enclosure protection rating. IP21, IP22 and IP54 are available as optional configurations, subject to the selected model and application.
Representative dimensions and weights for IP20 and IP54 configurations are provided under Ordering & Options. Final mechanical details are confirmed at quotation stage.
Front-panel control and monitoring are available, together with suitable remote communication and system-monitoring options where required. The control interface and communications protocol are agreed as part of the converter specification.
Approximate Dimensions and Weights | Standard IP20 Enclosures
The following dimensions and weights are representative of standard IP20 configurations.
| MODEL NUMBER | CAPACITY | DIMENSIONS W × D × H (mm) | WEIGHT |
|---|---|---|---|
| PXe-130001-M | 1kVA | 430 × 550 × 222 | 45 kg |
| PXe-130003-M | 3kVA | 430 × 600 × 267 | 60 kg |
| PXe-130006-M | 6kVA | 430 × 650 × 600 | 92 kg |
| PXe-130010-M | 10kVA | 430 × 650 × 600 | 110 kg |
| PXe-130015-M | 15kVA | 550 × 700 × 800 | 153 kg |
| PXe-130020-M | 20kVA | 550 × 700 × 800 | 177 kg |
| PXe-130030-M | 30kVA | 550 × 900 × 1000 | 273 kg |
| PXe-130045-M | 45kVA | 550 × 1000 × 1300 | 355 kg |
Approximate Dimensions and Weights | Optional IP54 Enclosures
| MODEL NUMBER | CAPACITY | DIMENSIONS W × D × H (mm) | WEIGHT |
|---|---|---|---|
| PXe-130001-M | 1kVA | 550 × 380 × 650 | 60 kg |
| PXe-130003-M | 3kVA | 550 × 550 × 530 | 75 kg |
| PXe-130006-M | 6kVA | 550 × 650 × 700 | 120 kg |
| PXe-130010-M | 10kVA | 550 × 650 × 700 | 160 kg |
| PXe-130015-M | 15kVA | 600 × 800 × 1000 | 280 kg |
| PXe-130020-M | 20kVA | 600 × 1000 × 1282 | 290 kg |
| PXe-130030-M | 30kVA | 600 × 1000 × 1282 | 350 kg |
| PXe-130045-M | 45kVA | 1000 × 700 × 1552 | 437 kg |
Note: Dimensions and weights are nominal and based on representative standard IP20 and optional IP54 configurations. Values for 6kVA to 45kVA use equivalent-capacity enclosure references and remain indicative for the selected M-Series configuration. Final values may vary depending on input current, specified voltage, operating frequency, transformer arrangement and optional equipment. Other configurations are available upon request, with confirmed dimensions and weights provided at quotation stage.
PXe-M Series Order Codes
You can derive a product order code from the main ordering information using the structure below.
The generic PXe-M Series model code follows the format PXe-130000-M. The first six digits identify the input and output phase arrangement and converter capacity.
For example, a 20kVA converter with single-phase input and three-phase output would use the base model:
PXe-130020-M
The complete order code can then identify the electrical configuration, enclosure and control arrangement:
PXe-130020-M-[INPUT]-[OUTPUT]-[RATING]-[ENCLOSURE]-[CONTROL]
Example:
PXe-130020-M-[1P230V50]-[3P400V60N]-[20KVA]-[IP20]-[MC]
This would represent:
(PXe-130020-M) – PX Electronics M-Series 20kVA Static Frequency Converter
(1P230V50) – Single-phase, 230V, 50Hz input
(3P400V60N) – Three-phase, 400V line-to-line, 60Hz output with neutral
(20KVA) – 20kVA rated capacity
(IP20) – Standard IP20 enclosure
(MC) – Manual Control
For this illustrative configuration, the complete order code would therefore be:
PXe-130020-M-1P230V50-3P400V60N-20KVA-IP20-MC
| MODEL | INPUT | OUTPUT | CAPACITY | ENCLOSURE | INTERFACE |
|---|---|---|---|---|---|
| PXe-130020-M M-Series Static Frequency Converter |
1P230V50 1P = Single Phase 230V = Input Voltage 50 = 50Hz |
3P400V60N 3P = Three Phase 400V = L-L Voltage 60 = 60Hz N = Neutral |
20KVA 20kVA capacity |
IP20 Standard enclosure |
MC Manual Control |
Alternative input and output voltages, frequencies, neutral arrangements and approved enclosure options can be specified according to the application. The final order code is confirmed when the converter configuration is agreed.
Additional Available Options
IP21, IP22 and IP54 Enclosures
IP20 is the standard enclosure rating. IP21, IP22 and IP54 configurations are available as options, subject to the selected model, cooling arrangements and installation conditions. Environmental suitability must be assessed separately, particularly where condensation, outdoor exposure or corrosive atmospheres are involved.
Alternative Output Voltages and Frequencies
Three-phase output voltages and operating frequencies can be selected according to the connected equipment. Fixed 50Hz and 60Hz outputs and selected 400Hz or specialist frequency arrangements are available subject to technical review.
Conformal Coating
Additional coating of selected internal PCBs and electronic components can be specified for installations where increased protection against humidity or potentially corrosive atmospheres is required.
19-inch Rack-Mount Construction
Available for suitable smaller configurations intended for installation in equipment racks, laboratory systems or production test installations. Rack capacity, mounting support, ventilation and connection access must be considered.
Communications and Remote Control
RS232C is the standard communications interface. RS485, Ethernet and GPIB can be specified for suitable controller configurations. Protocols, monitoring functions and remote-control requirements are confirmed for the selected system.
Remote Watchdog Monitoring
Independent monitoring can be considered for suitable larger systems and applications requiring additional fault supervision. Available alarm, event-logging, notification and controlled restart functions depend on the agreed monitoring and control configuration.
Input Harmonic Mitigation
Input filtering and harmonic mitigation requirements can be reviewed against the selected converter, available single-phase supply and site power-quality limits.
Cables and Terminations
Input and output cable assemblies, hard-wired terminals, industrial connectors and customer-specific connection arrangements can be specified according to the electrical rating and installation.
Mobile Base and Handling Options
Castors, wheeled bases and handling arrangements are available for suitable configurations where equipment must be moved between workshops, laboratories or production areas.
External Metering
External energy metering or branch-circuit monitoring can be incorporated where additional measurements or integration with customer-selected equipment are required.
Factory Acceptance Testing
Factory test documentation, customer-witnessed testing and third-party witnessed Factory Acceptance Testing can be arranged according to the agreed project requirements.
Information Required for Quotation
Please provide the available single-phase input voltage and frequency, maximum input current or supply capacity, required three-phase output voltage and frequency, continuous load rating and details of the connected equipment.
Where applicable, include motor starting or inrush current, load power factor, non-linear load characteristics, neutral and earthing requirements, operating duty, enclosure protection, installation space, cooling, connections and communications.
PX Electronics will review the electrical and mechanical requirements and confirm the proposed converter configuration, installation requirements and final dimensions and weights at quotation stage.
PXe-130000-M Series Specification
| Capacity | |
| Three Phase Output (Other options available on request) |
kVA Ratings: 1kVA, 3kVA, 6kVA, 10kVA, 15kVA, 20kVA, 30kVA, 45kVA |
| Input | |
| Single Phase (Select One Individual Voltage) |
110V, 115V, 120V, 127V, 220V, 230V, 400V (±10%, Other options available) |
| Frequency | 50Hz/60Hz ±5%, 400Hz (Optional) |
| Power Factor | ≥ 0.8 (standard type) ≥ 0.9 (optional type, 12 or 18 pulse) |
| Output | |
| Three Phase (Select Voltages required) |
Fixed: (L-N/L-L), 115V/200V, 120/208V, 127/220V, 220/380V, 230/400V, 240/415V, 254/440V, 277/480V, 400/690V, 3 Phase 3 Wire or 3 Phase 4 Wire Adjustable: Low range 0~260V/High range 0~520V, 3 Phase 3 Wire or 3 Phase 4 Wire |
| Frequency | Fixed: 50Hz, 60Hz, 100Hz, 200Hz, 45-200Hz (adjustable) Optional: 400Hz, 40Hz~500Hz (adjustable), 16.67Hz, 25Hz, 50Hz, 60Hz, 400-1000Hz |
| Voltage Accuracy | ≤ ±1% FS |
| Frequency Accuracy | ≤ ±0.1% FS |
| Total Harmonic Distortion | THD ≤ 3% @ linear load, pure sine wave output |
| Load Current Crest Factor Capability | 3:1 |
| Overload Capacity | 100% continuous <110% – 15 minutes, <125- 10 minutes, <150%- 1 minute, <200%- 5 seconds >200% output cut off (other variations available upon request) |
| Interface | RS232C std, RS485, GPIB, Ethernet (Optional) |
| Protection | Over-current, over-voltage, over-power, over-temp, short circuit, alarm and indicators |
| Enclosure IP Rating | IP20 (Standard), IP21, IP22 & IP54 (Optional). Special enclosure options available |
| LCD Display | Frequency meter, Voltage meter, Current meter, Power meter, PF meter |
| Connectors | Hard-wire terminals, EN60309, MIL-STD, or client choice |
| Operating conditions | |
| Temperature | Operation: -10℃~55℃ Ambient: -10℃~45℃ |
| Noise | ≤ 65dB at 1 meter EN 55022, IEC1000-4 |
| Humidity | 10~90% non-condensing |
| Cooling | Variable speed fan, filtered air intake in base, exhaust at rear |
| Altitude | ≤ 1800m |
| Castors or Feet | 0.5-3kVA have rubber feet and lifting handles, 4kVA+ have castors with front brakes. A/Vs or feet optional |
| Reliability and Efficiency | |
| Mean Time Between Failure (MTBF) | 50,000Hrs |
| Mean Time To Restore (MTTR) | < 30 min |
| Overall Efficiency | ≥ 85% |
| Standards | |
| CE, GB50054-95, GB 50150-1991, GB 50150-2006, GB 50171-1992, GB/T 16935.5-2008, GB/T16935.4-2011 | |
| EN IEC61000-3-2, EN 61000-3-3, EN55032, EN55035, MIL-STD-1399, MIL-STD 461, MIL-STD704, STANAG 1008 | |
| For more information and support, please feel free to contact us | |
No matching FAQs found.
A single-phase to three-phase Static Frequency Converter takes an available single-phase AC supply and generates a regulated three-phase AC output.
The system can also change the output voltage and frequency to match the connected equipment.
Yes. The PXe-M Series can be configured to convert 230V single-phase input into a regulated 400V three-phase output.
The system generates all three output phases and provides the required voltage through its inverter and transformer arrangement.
Yes, provided the converter is selected for the complete machine load.
The assessment should include motors, transformers, heaters, electronic supplies, control circuits and starting current, rather than relying only on the main motor rating.
Yes, but the converter must be sized for the starting current and its duration.
Direct-on-line motors and compressors can draw several times their normal running current. Soft starters or controlled starting can reduce the required peak capacity.
No. Increasing the voltage does not create additional electrical capacity.
The available output remains limited by the power and current that can be drawn from the single-phase input, together with converter losses.
Only the smallest ratings and loads may be suitable for a standard 13A outlet.
Most PXe-M Series converters require a dedicated circuit, protective device, isolator and industrial connection sized for the maximum input current.
The standard PXe-M Series range extends to 45kVA, providing three-phase output from a single-phase electrical supply.
Higher-capacity applications can be assessed individually, but suitability depends on the available input supply capacity, operating duty and connected load requirements.
Larger PXe-M Series converters generally require a dedicated, high-current single-phase electrical supply rather than a standard domestic or light-commercial circuit.
The supply must be assessed for continuous input current, converter losses, load power factor, starting demand and upstream protection. PX Electronics will review the available electrical supply before recommending the appropriate converter rating.
Yes. The range can convert a single-phase 50Hz input into a three-phase 60Hz output.
It can also be configured for single-phase 60Hz input to three-phase 50Hz output.
Yes. The output can be configured as three-phase three-wire or three-phase four-wire with neutral.
The expected phase imbalance, phase-to-neutral loads and neutral current should be stated when requesting a quotation.
Selected M Series configurations can provide three-phase 400Hz output. For dedicated aviation and avionics applications, the PX Electronics 400Hz SFC range may be the more appropriate starting point.
A VFD is primarily intended to control the speed and torque of a compatible motor. Its PWM output is normally connected directly to that motor.
The PXe-M Series provides a regulated three-phase AC supply. It can therefore support suitable complete machinery containing motors, transformers, control circuits, heaters and electronic power supplies.
A bypass can only continue supplying the load where an alternative three-phase source with the correct voltage, frequency and capacity is available.
A single-phase mains source cannot be connected directly to the three-phase load as a functional bypass.