PXe-400F-DC Series Aircraft 400Hz and 28Vdc Avionics Ground Power Units | GPU
PXe-330000-400F-DC Series
The PXe-400F-DC Series combines regulated 400Hz AC and 28Vdc aircraft ground power within a single, customer-configured system. Rather than selecting from a fixed range of combined AC and DC ratings, customers can specify the 400Hz AC capacity and 28Vdc current needed for their aircraft, avionics equipment or maintenance application.
The independent AC and DC power-conversion sections can operate simultaneously from a common incoming supply. Continuous AC load, DC current, short-duration starting demand and the available input supply are assessed together to establish the appropriate system configuration.
From lower-power avionics testing to higher-capacity aircraft maintenance and ground-support requirements, PX Electronics can provide application-specific combinations with suitable enclosures, output cables, connectors, control interfaces and protection arrangements.
Technical Highlights
Independently Specified AC and DC Ratings
Choose the 400Hz AC kVA capacity and 28Vdc continuous current separately, without being restricted to predetermined combinations.
Simultaneous AC and DC Operation
Independent AC and DC conversion sections share a common incoming supply and can operate together within the configured system ratings.
Continuous and Starting Current Requirements
The DC section can be specified around the continuous load and any additional short-duration current demand, including the required duration and duty cycle.
Regulated 400Hz Aircraft Power
Three-phase 115/200V or 120/208V 400Hz output can be configured for suitable aircraft applications. Adjustable AC output voltage is available on selected configurations.
Application-Specific Construction
Fixed or mobile enclosures, aircraft cables, connectors, interlocks, communications and protection arrangements are selected for the installation.
Solid-State Conversion and Monitoring
Static power conversion avoids rotating machinery. Local monitoring and suitable protective functions are incorporated according to the agreed AC and DC system design.
Product Information
PXe-400F-DC Series System Configuration
The PXe-400F-DC Series is configured around two separate output requirements: the continuous 400Hz AC load and the regulated 28Vdc load. Each output section is selected for its own electrical rating and operating duty.
The two conversion sections are integrated into a common cabinet and share one incoming electrical supply. Both outputs can operate simultaneously, provided the incoming supply, internal distribution, cooling and protection are rated for the combined demand.
This allows the customer to select an AC/DC combination appropriate to the equipment being powered, rather than selecting a larger or differently rated system solely because it is the nearest available catalogue model.
Illustrative 400Hz AC and 28Vdc Combinations
The following examples demonstrate the range of configurations that can be considered. They do not represent a restricted or fixed product list.
| 400Hz AC CAPACITY | 28Vdc CONTINUOUS CURRENT | CONFIGURATION STATUS |
|---|---|---|
| 5kVA | 20A | Illustrative combination; specification by quotation |
| 5kVA | 35A | Illustrative combination; specification by quotation |
| 6kVA | 100A | Customer-specific configuration; specification by quotation |
| 20kVA | 200A | Illustrative combination; specification by quotation |
| 30kVA | 600A | Previously manufactured configuration |
Configuration note: AC capacity and DC continuous current are selected independently. These examples are not fixed catalogue models or guaranteed performance combinations. Final ratings, starting-current capability, input supply requirements, dimensions and weights are confirmed individually at quotation stage.
Independent Outputs and Simultaneous Operation
The 400Hz AC and 28Vdc sections are independent power-conversion systems installed within a shared enclosure. They can supply their respective loads at the same time when the complete system is designed for that operating condition.
The available input supply must support the combined real-power demand of the AC and DC sections, including conversion losses. Starting current, transient loading, power factor, protection coordination and operating duty are assessed when the system is specified.
Previously Manufactured 30kVA AC + 28Vdc / 600A GPU
A previous PX Electronics configuration combined 30kVA three-phase 400Hz AC power with a regulated 28Vdc output rated at 600A continuous. The DC system was also specified to supply a 2,000A starting current for 10 seconds.
This demonstrates how continuous DC current and short-duration starting capability can be specified alongside the required AC output, without imposing the same DC rating on every AC capacity.
| PARAMETER | PREVIOUSLY MANUFACTURED CONFIGURATION |
|---|---|
| 400Hz AC capacity | 30kVA, three-phase |
| 28Vdc continuous output | 600A |
| DC starting capability | 2,000A for 10 seconds |
| Enclosure protection | IP22 |
| Nominal dimensions W × D × H | 1070 × 900 × 1300mm |
| Nominal net weight | 430kg |
Example note: These figures relate to a particular customer-specific 30kVA AC/600A DC system. The dimensions and weight are the latest nominal figures and are subject to confirmation for any subsequent configuration. Other AC/DC combinations will have their own electrical and mechanical specifications.
AC Output Voltage and Frequency
Common aircraft outputs include three-phase 115/200V or 120/208V at 400Hz, with neutral provided where required. The voltage arrangement, output current and control functions are selected for the connected aircraft or equipment.
An adjustable AC output is available for suitable configurations. The documented 30kVA example uses low- and high-voltage ranges of 0–260V and 0–520V respectively, both measured line-to-line. The final usable operating range and current limits are confirmed for the specified system.
Application and Installation Arrangements
The combined units can be configured for aircraft maintenance workshops, MRO facilities, avionics servicing, aerospace production, component testing and defence aviation support.
Enclosure construction, cooling, cable lengths, aircraft connectors, interlocks, mobility and communications are specified according to the operating environment and connected load. Final dimensions and weight are provided with the quotation.
Customer-Specific AC and DC Configuration
PXe-400F-DC Series Ground Power Units are specified according to the required AC and DC output ratings rather than selected from a fixed catalogue of combined capacities.
The 400Hz AC capacity, AC voltage, 28Vdc continuous current and any short-duration DC starting-current requirement are established independently. Input supply, enclosure, connections, protection and communications are then selected for the complete system.
Nominal dimensions and net weights are provided at quotation stage. These depend on the selected AC and DC ratings, transformer and cooling arrangements, enclosure protection, mobility and optional equipment.
PXe-400F-DC Series Order Codes
The order-code structure identifies the product family, incoming supply, first and second outputs, AC capacity, enclosure and control or communications interface.
PXe-330100-400F-DC-[INPUT]-[OUTPUT1]-[OUTPUT2]-[RATING]-[ENCLOSURE]-[INTERFACE]
The following example illustrates a three-phase 400V, 50Hz input; a three-phase 200V line-to-line, 400Hz output; and an additional 28Vdc output:
PXe-330100-400F-DC-3P400V50-3P200V400-28VDC-100KVA-IP20-RS485
This is an illustrative 100kVA AC order-code example, not a predefined combined AC/DC model. The required DC output current, peak current and duration are recorded separately in the quotation and customer-specific specification.
| MODEL | INPUT | OUTPUT 1 | OUTPUT 2 | CAPACITY | ENCLOSURE | INTERFACE |
|---|---|---|---|---|---|---|
| PXe-330100-400F-DC
Combined 400Hz AC + 28Vdc GPU |
3P400V50
Three-phase 400V L-L, 50Hz input |
3P200V400
Three-phase 200V L-L, 400Hz AC output |
28VDC
Regulated 28Vdc output; current specified separately |
100KVA
Rated AC output capacity |
IP20
Standard indoor enclosure |
RS485
Specified communications interface |
The final model number and order code are confirmed in the quotation. The output ratings remain subject to electrical and mechanical verification for the proposed application.
Additional Available Options
Enclosure Protection
IP20 is the standard indoor enclosure arrangement, with IP21, IP22 and IP54 options subject to the required configuration. IP22 and IP54 generally require redesigned enclosures, affecting dimensions, weight and cooling. Suitability for outdoor, marine or corrosive environments must be assessed separately.
Fixed and Mobile Construction
Floor-standing or mobile cabinet arrangements can be specified according to the converter size, operating location and handling requirements. Castors, feet, cable storage and other mobility provisions are selected for the completed system.
Adjustable 400Hz AC Output
Suitable configurations can provide adjustable AC output voltage. The previously manufactured 30kVA example used two line-to-line voltage ranges: 0–260V low range and 0–520V high range. Available voltage adjustment and output-current limits are confirmed for each system.
28Vdc Continuous and Starting Current
The 28Vdc output is selected for the required continuous current, with short-duration starting or peak-current capability specified separately where necessary. The requested current, duration, repetition rate and load characteristics must be provided.
Aircraft Cables, Connectors and Interlocks
Hard-wire terminals, industrial and aircraft-specific connectors, output cables and interlock arrangements can be specified. Cable lengths, current ratings, connection arrangements and voltage drop must be considered for both outputs.
Communications and Remote Control
Local control and monitoring can be supplemented by suitable communications interfaces, including RS485 and Ethernet arrangements where specified. The required protocol, monitoring functions and remote-control permissions are confirmed for the project.
Conformal Coating and Environmental Protection
Additional coating of selected internal electronic assemblies can be considered where humidity or atmospheric conditions require extra protection. Cooling, condensation, corrosion and enclosure requirements are reviewed as part of the complete installation.
Remote Fault Monitoring
Independent monitoring, alarms, fault-history recording and remote status reporting can be considered where required. The available functions depend on the selected monitoring and communications arrangement.
Factory Acceptance Testing
Factory test records, customer-witnessed testing and third-party witnessed Factory Acceptance Testing can be arranged according to the project requirements. Aircraft-specific power-quality verification and documentation are agreed before manufacture.
Information Required for Quotation
Please provide the available input voltage, phase and frequency; the required 400Hz AC voltage and continuous kVA; the 28Vdc continuous current; and any starting or peak-current requirement with its duration.
We will also need to establish whether both outputs operate simultaneously, the connected load characteristics, aircraft connector and cable requirements, neutral and earthing arrangements, enclosure protection, fixed or mobile installation, communications and any project-specific testing requirements.
PX Electronics will review these requirements and confirm the proposed AC/DC configuration, incoming supply demand, protection arrangements, dimensions, weight and final ordering code at quotation stage.
PXe-400F-DC Series Technical Specification
The PXe-400F-DC Series is a customer-configured combined 400Hz AC and 28Vdc Ground Power Unit. The following table describes available configuration choices rather than fixed ratings applicable to every system.
| PARAMETER | SERIES CONFIGURATION |
|---|---|
| System type | Combined solid-state 400Hz AC and 28Vdc Ground Power Unit |
| System arrangement | Independent AC and DC power-conversion sections within a shared enclosure and with a common input supply |
| Input supply | Voltage, phase, frequency and current capacity specified for the installation; three-phase 50Hz or 60Hz supply arrangements available subject to configuration |
| 400Hz AC capacity | Customer-selected continuous kVA rating |
| AC output voltage | Common aircraft configurations include 115/200V or 120/208V (L-N/L-L), three-phase; alternatives subject to application |
| AC output frequency | 400Hz |
| Adjustable AC output | Available on selected configurations. The documented dual-range option provides 0–260V L-L low range and 0–520V L-L high range; output-current limits confirmed per configuration |
| DC output voltage | 28Vdc regulated |
| DC continuous current | Customer-selected and specified independently of AC capacity |
| DC starting or peak current | Specified by required current, duration and operating duty; not a fixed series-wide rating |
| Simultaneous operation | AC and DC outputs can operate simultaneously within the configured system and common input-supply ratings |
| Output phase, neutral and earthing | Selected according to the aircraft load and installation; AC neutral and protective-earth arrangements defined in the project specification |
| Control and monitoring | Local control and operating-status monitoring; additional remote functions and interfaces according to configuration |
| Communications | RS485 and Ethernet interface arrangements available subject to the selected control system |
| Protection | Input and output protection coordinated with the agreed AC and DC ratings, including appropriate over-current, overload, short-circuit and thermal protection |
| Enclosure protection | IP20 standard indoor configuration; IP21, IP22 and IP54 alternatives subject to enclosure design and installation requirements |
| Installation | Fixed or mobile construction, with cooling, cable entry, access and handling arrangements defined for the system |
| Connections | Hard-wire or specified aircraft and industrial connectors, cable assemblies and interlocks according to application |
| Environmental requirements | Ambient temperature, humidity, altitude and ventilation requirements confirmed for the proposed installation and system specification |
| Dimensions and net weight | Provided at quotation stage for the selected AC/DC ratings and enclosure |
| Documentation and testing | Final project specification and applicable conformity documentation; additional FAT and customer-specific test requirements by agreement |
Specification note: This table describes configurable series capabilities, not a universal performance guarantee. Electrical ratings, regulation, overload limits, communications, environmental limits and compliance requirements are confirmed for each customer-specific unit.
Technical Reference | Previously Manufactured 30kVA AC + 600A DC Unit
The following values describe a particular PXe-330030-400F-DC configuration. They demonstrate a previously manufactured system and must not be assumed to apply to every PXe-400F-DC Ground Power Unit.
| PARAMETER | 30kVA + 600A EXAMPLE |
|---|---|
| Reference model | PXe-330030-400F-DC |
| Input supply | 415V L-L ±10%, three-phase, 50Hz |
| AC rated capacity | 30kVA, three-phase |
| AC output frequency | 400Hz |
| AC output low range | 0–260V line-to-line, adjustable |
| AC output high range | 0–520V line-to-line, adjustable |
| AC voltage accuracy | Better than ±1% full scale |
| AC frequency accuracy | Better than ±0.1% full scale |
| AC output THD | Less than 3% with linear load |
| DC output voltage | 28Vdc |
| DC continuous current | 600A |
| DC starting current | 2,000A for 10 seconds |
| Communications | RS485/Ethernet adaptor |
| Enclosure protection | IP22 |
| Nominal dimensions W × D × H | 1070 × 900 × 1300mm |
| Nominal net weight | 430kg |
Example qualification: The 30kVA data describes one configured unit. Other systems may have different voltage ranges, output current limits, starting performance, protection, communications and mechanical characteristics.
No matching FAQs found.
A combined 28Vdc and 400Hz Ground Power Unit supplies regulated AC and DC electrical power for aircraft maintenance, avionics testing, aerospace production and ground-support applications.
The PXe-400F-DC Series allows the AC capacity and DC current to be specified independently, providing both outputs within one integrated system.
Yes. The PXe-400F-DC Series is not restricted to predetermined AC/DC combinations.
Customers can specify the required 400Hz AC kVA capacity and 28Vdc continuous current separately. Starting-current requirements, output connections and installation arrangements are then incorporated into the proposed system specification.
Yes. The Ground Power Unit (GPU) is designed to provide simultaneous 28Vdc and 400Hz AC outputs, enabling multiple aircraft systems or test equipment to be powered simultaneously. This reduces the need for separate power units and improves operational convenience and efficiency.
The unit accepts a standard 50Hz or 60Hz power, depending on configuration. Input voltage and phase options can be specified to suit site requirements, including single-phase or three-phase supplies.
The PXe-400F-DC Series described here combines 400Hz AC and regulated 28Vdc aircraft power.
For applications requiring 270Vdc, PX Electronics offers the dedicated PXe-270DC Series. Customer requirements involving alternative combinations of AC and DC power can be reviewed separately.
Yes. The GPU uses advanced IGBT-based solid-state inverter technology and filters to deliver clean, low-distortion power with precise voltage and frequency control. This makes it suitable for sensitive avionics, aircraft electrical systems, and laboratory test environments.
Yes, where the DC section is designed for the required duty.
A previously manufactured PXe-400F-DC system combined 30kVA of 400Hz AC power with a 28Vdc output rated at 600A continuous and 2,000A starting current for 10 seconds.
Other starting-current ratings and durations are assessed individually and must not be assumed to apply to every configuration.
The system includes input-side circuit breakers and fuses to provide isolation and protection against over-current and electrical faults. Built-in electronic protection also monitors for overload, short circuit, over-voltage and over-temperature conditions.
These protection features help safeguard the Ground Power Unit, its internal components and the connected aircraft or test equipment during operation.
The 28Vdc/400Hz Ground Power Unit (GPU) is available in both fixed and mobile configurations. This makes it suitable for use in aircraft workshops, MRO maintenance facilities, production areas, and flight line support where flexibility or portability is required.
Each PXe-400F-DC system is configured around the customer’s AC and DC output requirements.
The selected power ratings, enclosure protection, cooling, connections and mobility arrangements affect the finished cabinet dimensions and weight. PX Electronics confirms these details once the proposed configuration has been established.
Outdoor operation can be accommodated where the GPU is specified with an appropriate enclosure and installation arrangement.
IP20 is intended for protected indoor installations. Higher-protection enclosures, including IP54, can be considered for demanding environments. However, suitability for rain, snow, condensation, corrosion and temperature extremes must be assessed for the particular installation. The required environmental protection is confirmed at the quotation stage.
A Ground Power Unit uses solid-state power electronics and is much lighter and more compact than rotating machinery. The GPU provides greater control over output voltage and frequency, as well as precise control of V and A protection. Unlike rotary machines, there are no mechanical maintenance requirements
Ground Power Units (GPU) fault diagnostic systems work by monitoring voltage, current, and power, as well as phase loss. These errors are written to Non-Volatile RAM (NVRAM). SIL Watch-dog options are available for independent monitoring and reporting.
Watchdog or independent fault monitoring is physically outside the GPU, meaning it does not rely on the GPU for its auxiliary power, so it can monitor and report the health of Ground Power Units, particularly high-kVA units with critical loads. These autonomous fault-diagnostic systems monitor voltage, current, power, and phase loss. These error conditions are written to Non-Volatile RAM (NVRAM) and can also be sent via VPN, networks, and SMS.