PXe-400F-DC Series Aircraft 400Hz and 28Vdc Avionics Ground Power Units | GPU

PXe-330000-400F-DC Series

The PXe-400F-DC Series combines regulated 400Hz AC and 28Vdc aircraft ground power within a single, customer-configured system. Rather than selecting from a fixed range of combined AC and DC ratings, customers can specify the 400Hz AC capacity and 28Vdc current needed for their aircraft, avionics equipment or maintenance application.

The independent AC and DC power-conversion sections can operate simultaneously from a common incoming supply. Continuous AC load, DC current, short-duration starting demand and the available input supply are assessed together to establish the appropriate system configuration.

From lower-power avionics testing to higher-capacity aircraft maintenance and ground-support requirements, PX Electronics can provide application-specific combinations with suitable enclosures, output cables, connectors, control interfaces and protection arrangements.

Technical Highlights

Independently Specified AC and DC Ratings

Choose the 400Hz AC kVA capacity and 28Vdc continuous current separately, without being restricted to predetermined combinations.

Simultaneous AC and DC Operation

Independent AC and DC conversion sections share a common incoming supply and can operate together within the configured system ratings.

Continuous and Starting Current Requirements

The DC section can be specified around the continuous load and any additional short-duration current demand, including the required duration and duty cycle.

Regulated 400Hz Aircraft Power

Three-phase 115/200V or 120/208V 400Hz output can be configured for suitable aircraft applications. Adjustable AC output voltage is available on selected configurations.

Application-Specific Construction

Fixed or mobile enclosures, aircraft cables, connectors, interlocks, communications and protection arrangements are selected for the installation.

Solid-State Conversion and Monitoring

Static power conversion avoids rotating machinery. Local monitoring and suitable protective functions are incorporated according to the agreed AC and DC system design.

PXe-400F-DC Series System Configuration

The PXe-400F-DC Series is configured around two separate output requirements: the continuous 400Hz AC load and the regulated 28Vdc load. Each output section is selected for its own electrical rating and operating duty.

The two conversion sections are integrated into a common cabinet and share one incoming electrical supply. Both outputs can operate simultaneously, provided the incoming supply, internal distribution, cooling and protection are rated for the combined demand.

This allows the customer to select an AC/DC combination appropriate to the equipment being powered, rather than selecting a larger or differently rated system solely because it is the nearest available catalogue model.

Illustrative 400Hz AC and 28Vdc Combinations

The following examples demonstrate the range of configurations that can be considered. They do not represent a restricted or fixed product list.

400Hz AC CAPACITY 28Vdc CONTINUOUS CURRENT CONFIGURATION STATUS
5kVA 20A Illustrative combination; specification by quotation
5kVA 35A Illustrative combination; specification by quotation
6kVA 100A Customer-specific configuration; specification by quotation
20kVA 200A Illustrative combination; specification by quotation
30kVA 600A Previously manufactured configuration

Configuration note: AC capacity and DC continuous current are selected independently. These examples are not fixed catalogue models or guaranteed performance combinations. Final ratings, starting-current capability, input supply requirements, dimensions and weights are confirmed individually at quotation stage.

Independent Outputs and Simultaneous Operation

The 400Hz AC and 28Vdc sections are independent power-conversion systems installed within a shared enclosure. They can supply their respective loads at the same time when the complete system is designed for that operating condition.

The available input supply must support the combined real-power demand of the AC and DC sections, including conversion losses. Starting current, transient loading, power factor, protection coordination and operating duty are assessed when the system is specified.

Previously Manufactured 30kVA AC + 28Vdc / 600A GPU

A previous PX Electronics configuration combined 30kVA three-phase 400Hz AC power with a regulated 28Vdc output rated at 600A continuous. The DC system was also specified to supply a 2,000A starting current for 10 seconds.

This demonstrates how continuous DC current and short-duration starting capability can be specified alongside the required AC output, without imposing the same DC rating on every AC capacity.

PARAMETER PREVIOUSLY MANUFACTURED CONFIGURATION
400Hz AC capacity 30kVA, three-phase
28Vdc continuous output 600A
DC starting capability 2,000A for 10 seconds
Enclosure protection IP22
Nominal dimensions W × D × H 1070 × 900 × 1300mm
Nominal net weight 430kg

Example note: These figures relate to a particular customer-specific 30kVA AC/600A DC system. The dimensions and weight are the latest nominal figures and are subject to confirmation for any subsequent configuration. Other AC/DC combinations will have their own electrical and mechanical specifications.

AC Output Voltage and Frequency

Common aircraft outputs include three-phase 115/200V or 120/208V at 400Hz, with neutral provided where required. The voltage arrangement, output current and control functions are selected for the connected aircraft or equipment.

An adjustable AC output is available for suitable configurations. The documented 30kVA example uses low- and high-voltage ranges of 0–260V and 0–520V respectively, both measured line-to-line. The final usable operating range and current limits are confirmed for the specified system.

Application and Installation Arrangements

The combined units can be configured for aircraft maintenance workshops, MRO facilities, avionics servicing, aerospace production, component testing and defence aviation support.

Enclosure construction, cooling, cable lengths, aircraft connectors, interlocks, mobility and communications are specified according to the operating environment and connected load. Final dimensions and weight are provided with the quotation.