PXe-F Series 400Hz Static Frequency Converter | SFC
PXe-330000-400-F Series
PX Electronics 330000-400-F Series 400Hz static frequency converters provide reliable frequency conversion from standard 50Hz or 60Hz power to a stable 400Hz AC output. Designed for avionics testing, aerospace production, aircraft maintenance and specialist 400Hz test environments, the range supports applications where precise output frequency, low noise and dependable continuous operation are required.
As part of the PXe static frequency converter range, these systems use solid-state IGBT conversion technology to deliver controlled aircraft-standard power for sensitive equipment, test benches and ground support applications. Common output configurations include 115/200V 400Hz and 120/208V 400Hz, with fixed or adjustable output options available depending on the test or installation requirement.
Technical Highlights for the PXe-330000-400-F Series 400Hz Static Frequency Conversion:
Stable 400Hz aircraft power
Converts standard 50Hz or 60Hz power input to a regulated 400Hz AC output, with common aviation configurations such as 115/200V and 120/208V.
Solid-state IGBT conversion
Uses AC to DC to AC static conversion with IGBT PWM control for precise frequency regulation and consistent output quality.
Galvanic isolation
Integrated transformer isolation provides electrical separation between input and output, helping support cleaner power for sensitive avionics and aircraft systems.
Line voltage drop compensation
Compensates for voltage losses along the 400Hz output cable, helping maintain the required voltage at the connected aircraft, test system or other 400Hz load, particularly where longer ground-power cables are used.
Harmonic Mitigation Strategy
Optional 12-pulse and 18-pulse rectifier technology reduces input current harmonic distortion by cancelling dominant lower-order harmonics, improving supply compatibility and overall power quality.
Low-noise operation
Designed for reduced acoustic and electrical noise in laboratories, workshops, and controlled test environments.
Monitoring and control options
Front panel metering displays voltage, current, frequency, power and system status, with optional adjustable output, remote control, RS485 and volt-free contacts available.
Product Information
PXe-F Series System Configuration
PXe-F Series 400Hz Static Frequency Converters provide regulated AC power for aircraft, avionics and specialist electrical equipment operating at 400Hz. The converters accept a suitable 50Hz or 60Hz mains supply and generate a controlled 400Hz output at the voltage and phase arrangement required by the connected load.
Common aviation configurations provide 115V line-to-neutral / 200V line-to-line or 120V line-to-neutral / 208V line-to-line, three-phase 400Hz output. Single-phase 400Hz converters and alternative input or output voltages are also available for suitable test and equipment applications.
The PXe-F Series includes compact bench and rack installations, mobile converters and larger floor-standing systems. The established range covers 1kVA to 50kVA, with larger and customer-specific configurations available following technical review.
Solid-state IGBT PWM conversion provides regulated sine-wave power with transformer isolation. The appropriate input supply, output current, load power factor, phase balance, starting demand and operating duty are assessed for each application.
Fixed-frequency 400Hz output is suitable for many aircraft component and maintenance applications. Adjustable output voltage and frequency, remote monitoring, aircraft connectors and line voltage drop compensation can be specified where required.
Popular Configurations
The following examples illustrate common single-phase and three-phase 400Hz power requirements. Other input voltages, output voltages and converter capacities can be specified according to the connected equipment.
| MODEL | CAPACITY | INPUT | OUTPUT |
|---|---|---|---|
| PXe-110005-400-F | 5kVA | 230V ±10% 50Hz Single Phase |
115V 400Hz Single Phase |
| PXe-130010-400-F | 10kVA | 230V ±10% 50Hz Single Phase |
115V L-N / 200V L-L 400Hz Three Phase + N |
| PXe-330015-400-F | 15kVA | 400V L-L ±10% 50Hz Three Phase |
115V L-N / 200V L-L 400Hz Three Phase + N |
| PXe-330020-400-F | 20kVA | 400V L-L ±10% 50Hz Three Phase |
115V L-N / 200V L-L 400Hz Three Phase + N |
| PXe-330030-400-F | 30kVA | 400V L-L ±10% 50Hz Three Phase |
115V L-N / 200V L-L 400Hz Three Phase + N |
| PXe-330045-400-F | 45kVA | 400V L-L ±10% 50Hz Three Phase |
115V L-N / 200V L-L 400Hz Three Phase + N |
Configuration note: These examples illustrate typical electrical arrangements and are not fixed specifications for every unit. Final input and output ratings, phase and neutral arrangements, output current limits and protection requirements are confirmed for the application.
400Hz Output and Aircraft Applications
PXe-F Series converters can support avionics testing, aircraft equipment maintenance, aerospace production and specialist 400Hz test benches. The required output voltage and connection arrangement are established according to the aircraft system or equipment under test.
Three-phase output can be specified with neutral where 115V or 120V line-to-neutral supplies are required. The system must be assessed for phase imbalance, neutral current and the maximum continuous load on each phase.
Adjustable Output and Test Applications
Where equipment testing requires more than a fixed 400Hz supply, selected converters can be supplied with adjustable output voltage or frequency. The available adjustment range and operating limits depend on the configured model.
The converter can be specified to support controlled test conditions for aircraft electrical components, instruments and other specialist loads.
Aircraft Cables and Voltage Drop Compensation
Longer 400Hz output cables can introduce voltage drop between the converter and the connected load. Line voltage drop compensation is available on suitable configurations to help maintain the required voltage at the point of use.
Aircraft connectors, interlock arrangements, cable lengths, cable ratings and output protection are specified according to the installation and equipment requirements.
Installation, Enclosures and Monitoring
The standard enclosure protection rating is IP20. IP21, IP22 and IP54 configurations are available subject to the selected model and installation requirements. IP22 and IP54 require different enclosure arrangements from the standard cabinet.
Compact, rack-mounted, mobile and floor-standing construction can be considered according to the converter rating and application. Cooling, cable entry, access clearances and handling requirements are established during specification.
Front-panel monitoring provides visibility of operating parameters and system status. Remote control, RS485 communications and volt-free status contacts are available for suitable configurations.
Representative dimensions and net equipment weights for standard IP20 and optional IP54 enclosures are shown under Ordering & Options.
Approximate Dimensions and Weights | Standard IP20 Enclosures
The following dimensions and weights are nominal values for representative PXe-F Series 400Hz Static Frequency Converters in standard IP20 enclosures. Dimensions are shown as width × depth × height.
| MODEL NUMBER | CAPACITY | DIMENSIONS W × D × H (mm) | NET WEIGHT |
|---|---|---|---|
| PXe-110001-400-F | 1kVA | 430 × 380 × 133 | 22 kg |
| PXe-130003-400-F | 3kVA | 430 × 600 × 267 | 60 kg |
| PXe-110005-400-F | 5kVA | 430 × 550 × 222 | 49 kg |
| PXe-330006-400-F | 6kVA | 430 × 650 × 600 | 92 kg |
| PXe-330010-400-F | 10kVA | 430 × 650 × 600 | 110 kg |
| PXe-330015-400-F | 15kVA | 550 × 700 × 800 | 153 kg |
| PXe-330020-400-F | 20kVA | 550 × 700 × 800 | 177 kg |
| PXe-330030-400-F | 30kVA | 550 × 900 × 1000 | 273 kg |
| PXe-330045-400-F | 45kVA | 550 × 1000 × 1300 | 355 kg |
Approximate Dimensions and Weights | Optional IP54 Enclosures
The following figures are representative of IP54 configurations with separately specified enclosure construction. Other phase arrangements and models can be assessed at quotation stage.
| MODEL NUMBER | CAPACITY | DIMENSIONS W × D × H (mm) | NET WEIGHT |
|---|---|---|---|
| PXe-110001-400-F | 1kVA | 550 × 330 × 550 | 41 kg |
| PXe-130003-400-F | 3kVA | 550 × 550 × 530 | 75 kg |
| PXe-110005-400-F | 5kVA | 550 × 380 × 650 | 60 kg |
| PXe-330006-400-F | 6kVA | 550 × 650 × 700 | 120 kg |
| PXe-330015-400-F | 15kVA | 600 × 800 × 1000 | 280 kg |
| PXe-330020-400-F | 20kVA | 600 × 1000 × 1282 | 290 kg |
| PXe-330030-400-F | 30kVA | 600 × 1000 × 1282 | 350 kg |
| PXe-330045-400-F | 45kVA | 1000 × 700 × 1552 | 437 kg |
Note: Dimensions and weights are nominal and based on representative IP20 and IP54 configurations. Final values can vary according to input and output voltages, phase arrangement, transformer design, enclosure protection, cooling, mounting and optional equipment. The 10kVA single-phase-input IP54 configuration and other configurations not listed above will have dimensions and weights confirmed at quotation stage.
PXe-F Series Order Codes
The PXe-F Series order code identifies the converter model, input and output electrical configuration, rated capacity, enclosure and control arrangement.
For example, a 45kVA converter with three-phase 400V 50Hz input and three-phase 115/200V 400Hz output uses the base model:
PXe-330045-400-F
The complete order-code structure is:
PXe-330045-400-F-[INPUT]-[OUTPUT]-[CAPACITY]-[ENCLOSURE]-[INTERFACE]
For a standard IP20, manually controlled version, the illustrative complete order code is:
PXe-330045-400-F-3P400V50-3P200V400N-45KVA-IP20-MC
| MODEL | INPUT | OUTPUT | CAPACITY | ENCLOSURE | INTERFACE |
|---|---|---|---|---|---|
| PXe-330045-400-F PXe-F Series 400Hz Static Frequency Converter |
3P400V50 3P = Three Phase 400V = Input L-L 50 = 50Hz |
3P200V400N 3P = Three Phase 200V = Output L-L 400 = 400Hz N = Neutral |
45KVA 45kVA rated capacity |
IP20 Standard enclosure |
MC Manual Control |
The example identifies a three-phase 400Hz output with neutral, providing approximately 115V line-to-neutral from a 200V line-to-line supply. Alternative configurations may require a different complete order code. The final code is confirmed in the quotation.
Additional Available Options
IP21, IP22 and IP54 Enclosures
IP20 is the standard enclosure rating. IP21 protection can generally be provided using the same enclosure, subject to the selected model. IP22 and IP54 require different cabinet construction and may change the dimensions, weight, cooling and connection arrangements. Environmental suitability is confirmed for the installation.
Adjustable Output Voltage and Frequency
Selected converters can be specified with adjustable 400Hz output voltage and frequency functions for aircraft equipment testing, production validation and specialist electrical applications. The adjustment range and available output current depend on the configured system.
400Hz Aircraft Cables and Connectors
Aircraft-compatible output cables, hard-wire terminals, industrial connectors and customer-specified connection arrangements are available. Cable length, conductor ratings, termination type and any aircraft interlock requirements are reviewed for the application.
Line Voltage Drop Compensation
Output cable voltage drop compensation can be included where cable length and connected equipment requirements make it necessary. The compensation arrangement and operating limits are confirmed for the specified converter.
Remote Control and Communications
Remote control panels, RS485 communications and volt-free status contacts can be provided on suitable configurations. Communication protocols, remote functions and installation distances are confirmed according to the required interface.
Input Harmonic Mitigation
Optional 12-pulse and 18-pulse rectifier arrangements can be considered for suitable three-phase-input systems where reduced input current harmonic distortion is required. The appropriate solution depends on converter capacity and the installation supply.
Conformal Coating
Additional protective coating can be specified for selected internal electronic assemblies where humidity or other environmental conditions require increased protection. Overall enclosure suitability is assessed separately.
19-inch Rack-Mount Construction
Available for suitable smaller converters intended for installation within existing test racks, laboratory systems or production equipment. Mechanical support, ventilation and connection access must be considered.
Mobile Base and Handling Arrangements
Mobile bases, castors, feet and suitable handling provisions are available according to enclosure size, weight and installation requirements. Aviation ground-support applications may require additional cable storage, connection and mobility arrangements.
Remote Fault Monitoring
Independent monitoring and fault reporting can be considered for installations requiring remote supervision. Available alarm functions, event records, communication methods and remote-control permissions depend on the specified monitoring system.
Factory Acceptance Testing and Documentation
Factory test records, customer-witnessed testing and third-party witnessed Factory Acceptance Testing can be arranged according to the project requirements. Any aircraft-specific power-quality or compliance requirements must be agreed before manufacture.
Information Required for Quotation
Please provide the available input voltage, frequency, phase arrangement and supply capacity, together with the required 400Hz output voltage, phase arrangement, continuous kVA rating and connected load details.
For aircraft and specialist applications, please also specify load power factor, phase imbalance, inrush requirements, duty cycle, output cable length, connector and interlock requirements, neutral and earthing arrangements, enclosure protection, mobility, communications and any applicable testing requirements.
PX Electronics will confirm the proposed configuration, final mechanical dimensions, net weight, installation arrangements and complete order code at quotation stage.
PXe-330000-400-F Series Technical Specification
| Input | |
| Voltage | 400V or 440V ±10%, 3-phase or User Specified (single phase optional) |
| Frequency | 50Hz or 60Hz ±5%, 400Hz optional |
| Power Factor | >0.98 @ full load |
| Susceptibility | EN 61000-4-4, EN 61000-4-5 |
| Output | |
| Voltage | (L-N/L-L) 115/200V or 120/208V, 3-phase or User Specified |
| Voltage Regulation (Steady-State) | ±2% |
| Voltage Regulation (Dynamic) | ±5% @ 0–100% step-load |
| Frequency | 400Hz ±0.1% under all conditions |
| THDv | Better than 3% @ linear load |
| Overall Quality | Better than MIL-STD-704E, DFS400 |
| Waveform | Pure sinusoid |
| Phase Angle Accuracy | Better than 1% |
| Overload Capability | 100% continuous, 110% @ 30 mins, 150% 15 minutes, 200% @ 5 secs, 300% @ 1 sec |
| Permissible Load Power Factor | 0.6 leading to 0.6 lagging |
| Permissible Phase Unbalance | 70% |
| Secondary 28VDC Output | See our PXe-400-F-DC combi range of SFCs |
| Protection | |
| Input Supply | MCB, phase-loss detection, over & under voltage |
| Output | Over-current, over-voltage, over-power, over-temp, phase-loss detection, short-circuit (any phase) |
| Display Panel | |
| Parameters Displayed | Output voltage (ph-ph + ph-N), output current, power, frequency, power factor |
| Accuracy | Better than Class 0.25 IEC 60688 |
| LED Indicators | Input present, converter healthy, over-temperature, overload, general fault |
| Operating conditions | |
| Ambient Temperature Range | -10°C to 50°C |
| Electrical Noise | EN 55022, IEC1000-4 |
| Cabinet Protection | IP20 (Standard); IP21, IP22 and IP54 (Optional), subject to model and installation requirements. |
| Acoustic Noise | <50 dB(A) @ 1m |
| Construction | Mild steel, zinc plated, painted RAL7032 grey & white |
| Castors or Feet | 4kVA model includes rubber feet & lifting handles. Larger models include 80mm castors with front brakes. Anti-vibration mounts or feet optional |
| Cooling | Variable speed turbine, air intake in base, exhaust at rear |
| Connectors | |
| Connector Options | Hard-wire terminals, EN60309, MIL-STD, or client specification (400Hz Aircraft Interlock options available) |
| Remote Facilities | |
| Remote Control Option | Remote control panel, electrically isolated from converter, self-powered, On/Off + 5 status indications, operational up to 200m |
| Remote Monitoring | RS485 2-wire/0V, ½ duplex ¼ unit load, MODBUS RTU 16-bit CRC, 4800 or 9600 baud |
| Volt-Free Contacts (C/O) | Input supply present, output on/off, over-temperature, overload, fault. Contacts isolated from converter |
| Connector Type (Remote) | 25-way “D” socket |
| Options | |
| Variable Output Voltage | Front panel adjustment ±15% nominal voltage |
| Variable Output Frequency | Front panel adjustment 400Hz ±10% |
| Special Input Voltages | 220V & 480V (3-phase) |
| Special Output Voltages | 67/115V, 3-phase, 400Hz |
| Military EMC Standard | MIL-STD-461, MIL-STD-704, STANAG 1008 |
| Standards | |
| CE, EN61000-6-4, EN62040-1-1, EN55032, EN55035, EN IEC61000-3-2, EN61000-3-3, GB50054-95, GB50150-1991, GB50150-2006, GB50171-1992, GB/T16935.5-2008, GB/T16935.4-2011 |
|
No matching FAQs found.
A 400Hz Static Frequency Converter converts standard 50Hz or 60Hz mains power into 400Hz AC output. It is commonly used for avionics testing, aerospace production, MRO facilities, aircraft equipment testing and specialist 400Hz power applications.
Common aircraft 400Hz output configurations include 115/200V and 120/208V. The correct output voltage depends on the aircraft system, test bench or ground support application.
Yes. PXe 400Hz Static Frequency Converters can be configured to operate from standard 50Hz or 60Hz mains input supplies, depending on the site power available and the required output.
Yes. The converter is suitable for avionics laboratories, aircraft equipment testing and aerospace workshops where stable 400Hz AC power is required for sensitive systems.
PX will need to confirm the available input supply, required output voltage, output phase arrangement, kVA rating, load type, duty cycle, enclosure format and any remote control or communication requirements.
Yes. Adjustable output options can be provided where engineers need to test equipment across different voltage or frequency conditions.
A standard Static Frequency Converter may be configured for 50Hz to 60Hz or 60Hz to 50Hz conversion. A 400Hz static frequency converter is specifically designed to provide aircraft-standard 400Hz output for aviation, avionics and specialist test applications.
Aircraft use 400Hz power because higher frequency electrical systems allow transformers, motors and associated equipment to be smaller and lighter than equivalent 50Hz or 60Hz systems. This makes 400Hz power well suited to aviation applications.
Static Frequency Converter SFC fault diagnostic systems work by monitoring voltage, current and power and phase loss. These errors are written to Non-Volatile RAM (NVRAM). SIL Watch-dog options are available for independent monitoring and reporting.
Watch-dog or independent fault-monitoring systems are available to monitor and report the health of Static Frequency Converters, particularly high-kVA units. These autonomous fault-diagnostic systems monitor voltage, current, power, and phase loss. These errors are written to Non-Volatile RAM (NVRAM) and can be sent via Networks and SMS.