PXe-S Series Single Phase Static Frequency Converter | SFC
PXe-110000-S Series
PX Electronics PXe-110000-S Series single phase static frequency converters provide compact AC frequency conversion for laboratories, test benches, avionics workshops, marine equipment and specialist single phase loads. Designed for weight and compactness for 50Hz to 60Hz, 60Hz to 50Hz and selected 400Hz output requirements, the range allows engineers to operate or validate equipment under the correct supply frequency without relying on utility power conditions.
Compact models suit smaller technical installations, while higher-rated systems can be configured for continuous-duty operation, voltage matching, and remote monitoring. Typical uses include product testing, operation of imported equipment, export validation, aerospace equipment checks, and controlled laboratory power applications.
Product Information
PXe-S Series System Configuration
PXe-S Series single-phase Static Frequency Converters can be configured to suit the available input supply, required output voltage and frequency, connected load and installation requirements.
Typical applications include 50Hz to 60Hz and 60Hz to 50Hz conversion for imported equipment, export testing, laboratories and specialist electrical loads. Selected 400Hz and other frequency configurations are also available for suitable applications.
The range includes compact converters for lower-power bench and laboratory installations, together with higher-capacity systems for continuous-duty operation. Input and output voltages, fixed or adjustable frequency arrangements, and installation formats are selected according to the application.
Standard IP20 models include 1kVA, 2kVA, 3kVA, 5kVA and 7.5kVA configurations. Larger-capacity systems and alternative enclosure arrangements can also be specified according to customer requirements.
The converters use solid-state IGBT PWM conversion with transformer isolation and sine-wave AC output. Front-panel monitoring provides visibility of key operating parameters, with additional control and communications arrangements available where required.
Popular Configurations
The following examples illustrate common single-phase voltage and frequency conversion duties. Alternative electrical configurations can be specified to meet customer requirements.
| MODEL | CAPACITY | INPUT | OUTPUT |
|---|---|---|---|
| PXe-110001-S | 1kVA | 230V ±10% 50Hz Single Phase |
115V 60Hz Single Phase |
| PXe-110002-S | 2kVA | 230V ±10% 50Hz Single Phase |
115V 60Hz Single Phase |
| PXe-110003-S | 3kVA | 115V ±10% 60Hz Single Phase |
230V 50Hz Single Phase |
| PXe-110005-S | 5kVA | 115V ±10% 60Hz Single Phase |
230V 50Hz Single Phase |
Configuration note: These are representative electrical configurations, not fixed model limitations. The 7.5kVA model and other available capacities can be specified with electrical characteristics appropriate to the application. Final input and output ratings, operating limits and transient load requirements are confirmed for each configuration.
Installation Configurations
Smaller PXe-S Series models can be installed in laboratories, on benches or in suitable rack-mounted arrangements. Higher-capacity converters can be supplied in floor-standing or mobile enclosures, depending on the electrical rating, installation and handling requirements.
IP20 is the standard enclosure protection rating. IP21, IP22 and IP54 are available as optional configurations, subject to the selected model, cooling arrangements and installation requirements.
The enclosure format, ventilation, electrical connections and maintenance access are agreed against the selected converter and site conditions. Representative IP20 and IP54 dimensions and weights for models from 1kVA to 7.5kVA are provided under Ordering & Options.
Where a non-standard phase arrangement is required, the application can be assessed against the available supply, output current, load characteristics and required converter capacity.
Approximate Dimensions and Weights | Standard IP20 Enclosures
| MODEL NUMBER | CAPACITY | DIMENSIONS W × D × H (mm) | WEIGHT |
|---|---|---|---|
| PXe-110001-S | 1kVA | 430 × 380 × 133 | 22 kg |
| PXe-110002-S | 2kVA | 430 × 450 × 178 | 30 kg |
| PXe-110003-S | 3kVA | 430 × 450 × 178 | 31 kg |
| PXe-110005-S | 5kVA | 430 × 550 × 222 | 49 kg |
| PXe-110007.5-S | 7.5kVA | 430 × 550 × 630 | 84 kg |
Approximate Dimensions and Weights | Optional IP54 Enclosures
| MODEL NUMBER | CAPACITY | DIMENSIONS W × D × H (mm) | WEIGHT |
|---|---|---|---|
| PXe-110001-S | 1kVA | 550 × 330 × 550 | 41 kg |
| PXe-110002-S | 2kVA | 550 × 330 × 550 | 48 kg |
| PXe-110003-S | 3kVA | 550 × 330 × 550 | 50 kg |
| PXe-110005-S | 5kVA | 550 × 380 × 650 | 60 kg |
| PXe-110007.5-S | 7.5kVA | 550 × 550 × 730 | 126 kg |
Note: Dimensions and weights are nominal and based on representative IP20 and IP54 configurations. Final values may vary depending on the specified voltage, operating frequency, transformer arrangement and optional equipment. Other capacities and enclosure configurations, including IP21 and IP22, are available with dimensions and weights specified on a case-by-case basis. Confirmed mechanical details will be provided before manufacture.
PXe-S Series Order Codes
You can derive a product order code from the main ordering information using the structure below.
The generic PXe-S Series order code follows the format PXe-110000-S. The first six digits identify the phase configuration and converter capacity.
For example, a 3kVA converter with single-phase input and single-phase output would use the base model:
PXe-110003-S
The complete order code can then identify the electrical configuration, enclosure and control arrangement:
PXe-110003-S-[INPUT]-[OUTPUT]-[RATING]-[ENCLOSURE]-[CONTROL]
Example:
PXe-110003-S-[1P115V60]-[1P230V50]-[3KVA]-[IP20]-[MC]
This would represent:
(PXe-110003-S) – PX Electronics PXe-S Series Static Frequency Converter, 3kVA
(1P115V60) – Single-phase, 115V, 60Hz input
(1P230V50) – Single-phase, 230V, 50Hz output
(3KVA) – 3kVA rated capacity
(IP20) – Standard IP20 enclosure
(MC) – Manual Control
For this illustrative configuration, the complete part number would therefore be:
PXe-110003-S-1P115V60-1P230V50-3KVA-IP20-MC
| MODEL | INPUT | OUTPUT | CAPACITY | ENCLOSURE | INTERFACE |
|---|---|---|---|---|---|
| PXe-110003-S S-Series Static Frequency Converter |
1P115V60 1P = Single Phase 115V = Input Voltage 60 = 60Hz |
1P230V50 1P = Single Phase 230V = Output Voltage 50 = 50Hz |
3KVA 3kVA capacity |
IP20 Standard enclosure |
MC Manual Control |
Alternative input and output voltages, operating frequencies, phase arrangements and enclosure specifications can be incorporated into the order code according to the application.
Additional Available Options
IP21, IP22 and IP54 Enclosure Options
IP20 is the standard enclosure rating. IP21, IP22 and IP54 configurations are available as options, subject to the selected capacity, cooling arrangements and installation requirements. Environmental suitability must be assessed separately, particularly where the installation involves outdoor exposure, condensation or potentially corrosive atmospheres.
Conformal Coating
Additional coating of internal PCBs and selected electronic components can be specified where increased protection from humidity or potentially corrosive atmospheres is required.
19-inch Rack-Mount Construction
Available for suitable smaller configurations intended for integration into equipment racks, laboratory systems or production test installations.
Communications and Remote Control
RS232C, RS485, Ethernet and GPIB interfaces are available for suitable controller configurations. The required protocol, monitoring functions and remote-control arrangement are confirmed for the selected converter.
Remote Watchdog Monitoring
Independent fault-monitoring arrangements can be considered for selected larger converters, typically above 50kVA. Available notification, data logging and remote-control functions depend on the agreed system specification.
Cables and Terminations
Input and output cable assemblies, industrial connectors, hard-wired terminations and customer-specific connection arrangements can be specified to suit the installation.
Mobile Base and Handling Options
Wheeled bases, castors and suitable handling arrangements can be incorporated where equipment needs to be moved between production, test or service areas. Selection depends on converter weight, enclosure dimensions and site conditions.
Information Required for Quotation
Please provide the available input voltage and frequency, required output voltage and frequency, continuous load rating, and details of the equipment being powered.
Where relevant, include starting or inrush current, load power factor, non-linear load characteristics, operating duty, required enclosure protection, mounting arrangements, electrical connections and communications requirements.
PX Electronics will review the application and confirm the appropriate electrical configuration and mechanical details before manufacture.
PXe-110000-S Series Technical Specification
| Capacity | |
| Single Phase Output (Other options available on request) |
kVA Ratings: 0.5kVA, 1kVA, 2kVA, 3kVA, 5kVA, 7.5kVA, 10kVA, 15kVA, 20kVA, 30kVA, 50kVA, 60kVA, 75kVA, 100kVA, 150kVA, 200kVA |
| Input | |
| Single Phase (Select One Individual Voltage) |
110V, 115V, 120V, 127V, 220V, 230V, 400V (±10%, other options available) |
| Frequency | 50Hz/60Hz ±5%, 400Hz (Optional) |
| Power Factor | ≥ 0.8 (standard type) ≥ 0.9 (optional type, 12 or 18 pulse) |
| Output | |
| Single Phase (Select One Individual Voltage) |
Fixed: 110V, 115V, 120V, 127V, 220V, 230V, 240V, 400V, 28Vdc Adjustable: 0~300V |
| Frequency | Fixed: 50Hz, 60Hz, 100Hz, 200Hz, 45-200Hz (adjustable) Optional: 400Hz, 40Hz~500Hz (adjustable), 16.67Hz, 25Hz, 50Hz, 60Hz, 400-1000Hz |
| Voltage Accuracy | ≤ ±1% FS |
| Frequency Accuracy | ≤ ±0.1% FS |
| Total Harmonic Distortion | THD ≤ 3% @ linear load, pure sine wave output |
| Load Current Crest Factor Capability | 3:1 |
| Overload Capacity | 100% continuous <110% – 15 minutes, <125- 10 minutes, <150%- 1 minute, <200%- 5 seconds >200% output cut off (other variations available upon request) |
| Interface | RS232C std, RS485, GPIB, Ethernet (Optional) |
| Protection | Over-current, over-voltage, over-power, over-temp, short circuit, alarm and indicators |
| Enclosure IP Rating | IP20 (Standard), IP21, IP22 & IP54 (Optional). Special enclosure options available |
| LCD Display | Frequency meter, Voltage meter, Current meter, Power meter, PF meter |
| Connectors | Hard-wire terminals, EN60309, MIL-STD, or client choice |
| Operating conditions | |
| Temperature | Operating ambient temperature: -10℃~50℃ |
| Noise | ≤ 65dB at 1 meter EN 55022, IEC1000-4 |
| Humidity | 10~90% non-condensing |
| Cooling | Variable speed fan, filtered air intake in base, exhaust at rear |
| Altitude | ≤ 1800m |
| Castors or Feet | 0.5-3kVA have rubber feet and lifting handles, 4kVA+ have castors with front brakes on standard IP20 models. A/Vs or feet optional |
| Reliability and Efficiency | |
| Mean Time Between Failure (MTBF) | 50,000Hrs |
| Mean Time To Restore (MTTR) | < 30 min |
| Overall Efficiency | ≥ 85% |
| Standards | |
| CE, GB50054-95, GB 50150-1991, GB 50150-2006, GB 50171-1992, GB/T 16935.5-2008, GB/T16935.4-2011 | |
| EN IEC61000-3-2, EN 61000-3-3, EN55032, EN55035, MIL-STD-1399, MIL-STD 461, MIL-STD704, STANAG 1008 | |
| For more information and support, please feel free to contact us | |
No matching FAQs found.
A single phase Static Frequency Converter is used to convert electrical power from one voltage and frequency to another, typically from 230V 50Hz to 115V 60Hz, 60Hz to 50Hz and to 400Hz. This allows testing of AC-powered electronic modules, small motors and other single phase equipment where appropriate supply voltage and frequency must be connected
Yes, the PX Electronics single phase Static Frequency Converters converts 50Hz to 60Hz and can be configured for 60Hz to 50Hz or 50/60Hz to 400Hz
Yes. The SFC system can convert 60Hz to 50Hz. This is useful when operating European or UK equipment in the US, Canada and South America regions where the available AC power supply is 60Hz
Key information includes the available input supply voltage and frequency, output voltage and frequency, load power rating kVA, load type, knowledge of starting or inrush current, indoor/outdoor operating environment and any control or communication requirements like EtherNet RS485
Yes, the PXe-S Series SFC can be used for imported or export equipment testing. Manufacturers can use a 50Hz to 60Hz or 60Hz to 50Hz static frequency converter to test equipment under the same operating electrical conditions as the destination country. This is useful for validation, factory acceptance testing and production quality checks
Yes. Compact single phase SFC models are well suited to laboratories and bench testing, product validation areas and technical workshops where controlled AC voltage and frequency output is required
Yes, a single phase Static Frequency Converter (SFC) can convert to three phase 50Hz, 60Hz and 400Hz along with various voltage options. Our PXe M-Series supports this application.
Yes. PX Electronics can provide custom configurations to suit different voltages, frequencies, power ratings, enclosure types, control and monitoring requirements. This is particularly useful for industrial, marine and export testing applications where standard supply conditions do not match those of the connected equipment
A Static Frequency Converter uses solid-state power electronics and is much lighter and more compact than rotating machinery. The SFC provides greater control over output voltage and frequency, along with precise voltage and current protection. Unlike rotary machines, there are no mechanical maintenance requirements
Static Frequency Converter (SFC) fault diagnostic systems work by monitoring temperature, voltage, current, power and phase loss. These errors are written to Non-Volatile RAM (NVRAM) for later viewing. SIL Safety Integrity Level "Watch-Dog" options are available for independent monitoring and reporting
Watch-dog or independent fault-monitoring systems are available for monitoring and reporting the health of Static Frequency Converters, particularly high kVA units. These autonomous fault diagnostic systems work by monitoring temperature, voltage, current, power, and phase loss. The Watch Dog provides monitoring even with catastrophic power loss, errors can be written to Non-Volatile RAM, Networks and sent via SMS or VPN