PXe-R Series 19-Inch Rack Mount Static Frequency Converters
PXe-110000-R Series
PXe-R Series 19-Inch Rack Mount Static Frequency Converters
PX Electronics PXe-R Series 19-Inch Rack Mount Static Frequency Converters provide compact AC voltage and frequency conversion for integration into equipment racks, laboratory systems, production test installations and specialist electrical equipment.
Available in configurations up to 5kVA, the R-Series is intended for applications that require the functionality of a conventional Static Frequency Converter in a standard 19-inch rack installation. Systems can be configured for common 50Hz and 60Hz conversion duties, with 400Hz and other specialist output frequencies available where required.
Rather than treating rack mounting simply as an enclosure option, the PXe-R Series is designed around rack integration. Cooling, mounting, electrical connections, controls and communications are considered as part of the complete installation.
The solid-state conversion stage provides controlled sine-wave AC output, with output voltage, frequency and control arrangements selected around the connected load. Local operation can be combined with remote communications and stored settings, as required.
Technical Highlights
Purpose-Built 19-Inch Rack Integration
Designed specifically for installation within standard 19-inch equipment racks, test systems and technical cabinets, with cooling, connections and operator access considered as part of the rack arrangement.
50Hz, 60Hz & 400Hz Frequency Conversion
Supports common 50Hz to 60Hz and 60Hz to 50Hz conversion duties, with selected 400Hz and specialist-frequency configurations available for laboratory, avionics and equipment-testing applications.
Compact Static Frequency Conversion up to 5kVA
Provides AC voltage and frequency conversion in a space-efficient rack-mounted format for loads up to 5kVA, subject to the required voltage, frequency and load characteristics.
Peak Current Capability for Inrush Loads
Selected configurations provide increased short-duration peak-current capability for equipment with starting or energisation current above its normal running current. Required inrush performance should be confirmed when the converter is specified.
Local Monitoring, Stored Settings & Remote Integration
Front-panel control and measurement can be combined with stored operating setups and communication interfaces to connect to computers, PLCs, and automated test systems.
Product Information
PXe-R Series System Configuration
PX Electronics PXe-R Series 19-Inch Rack Mount Static Frequency Converters are configured around the available input supply, required output voltage and frequency, load capacity and phase arrangement.
The range is available from 0.5kVA to 5kVA and can be supplied with single-phase or three-phase input and output configurations. This includes single-phase to single-phase, single-phase to three-phase, three-phase to single-phase and three-phase to three-phase conversion.
Typical applications include 50Hz to 60Hz, 60Hz to 50Hz and 50/60Hz to 400Hz frequency conversion, with output voltage selected to suit the connected equipment. This allows the R-Series to perform voltage, frequency and phase conversion within the same rack-mounted system.
All models use a compact 19-inch rack format. Chassis depth and rack height increase with power rating while retaining a nominal 430mm chassis width.
RS232 communication is fitted as standard. RS485, GPIB or Ethernet interfaces can be specified for integration with laboratory equipment, automated test systems, PLCs or remotely controlled installations.
Popular Configurations
The configurations below illustrate typical PXe-R Series applications. Alternative input voltages, output voltages, frequencies and phase arrangements can be supplied according to the connected load and available mains supply.
| Model | Capacity | Input | Output | Dimensions |
|---|---|---|---|---|
| PXe-110000.5-R | 0.5kVA | 230V, 50Hz Single Phase |
115V, 60Hz Single Phase |
430 × 380 × 133mm |
| PXe-110001-R | 1kVA | 230V, 50Hz Single Phase |
115V, 60Hz Single Phase |
430 × 380 × 133mm |
| PXe-110002-R | 2kVA | 115V, 60Hz Single Phase |
230V, 50Hz Single Phase |
430 × 450 × 178mm |
| PXe-110003-R | 3kVA | 230V, 50Hz Single Phase |
115V, 400Hz Single Phase |
430 × 450 × 178mm |
| PXe-330005-R | 5kVA | 400V, 50Hz Three Phase |
115/200V, 400Hz Three Phase |
430 × 550 × 222mm |
Configuration note: The examples above are representative, not limiting. PXe-R systems can also be configured for single-phase to three-phase or three-phase to single-phase conversion, together with alternative voltages and 50Hz, 60Hz or 400Hz outputs.
Phase Configuration
The PXe-R model number identifies the input and output phase arrangement.
| Phase Code | Configuration |
|---|---|
| 110 | Single-phase input / Single-phase output |
| 130 | Single-phase input / Three-phase output |
| 310 | Three-phase input / Single-phase output |
| 330 | Three-phase input / Three-phase output |
Rack Integration
The PXe-R Series is designed specifically for standard 19-inch equipment racks. The mechanical format depends on the converter rating.
| Capacity | Dimensions | Approx. Rack Height |
|---|---|---|
| 0.5kVA / 1kVA | 430 × 380 × 133mm | 3U |
| 2kVA / 3kVA | 430 × 450 × 178mm | 4U |
| 5kVA | 430 × 550 × 222mm | 5U |
Allow sufficient rack depth, ventilation and service access around the converter. Confirm final mechanical requirements for the selected electrical configuration.
Communications
RS232 is provided as standard for connection to computers and external control equipment.
Optional interfaces include RS485, GPIB and Ethernet.
Specify the required interface in the quotation where the converter will form part of an automated test, laboratory, or remote-control system.
PXe-R Series Ordering & Options
PXe-R Series model numbers identify the converter phase arrangement and power rating. The complete system is then configured around the required input voltage and frequency, output voltage and frequency, communications interface and application-specific options.
PXe-R Series Model Number
The basic model-number format is:
PXe-[PHASE CONFIGURATION][CAPACITY]-R
For example:
PXe-110003-R
This identifies a 3kVA PXe-R Series 19-inch rack mount Static Frequency Converter with single-phase input and single-phase output.
Model Number Structure
| Code | Function | Meaning |
|---|---|---|
| 110 | Phase Configuration | Single-phase input / Single-phase output |
| 130 | Phase Configuration | Single-phase input / Three-phase output |
| 310 | Phase Configuration | Three-phase input / Single-phase output |
| 330 | Phase Configuration | Three-phase input / Three-phase output |
| 000.5 | Capacity | 0.5kVA |
| 001 | Capacity | 1kVA |
| 002 | Capacity | 2kVA |
| 003 | Capacity | 3kVA |
| 005 | Capacity | 5kVA |
| R | Series | PXe-R Series 19-inch rack mount construction |
Available Models
| Capacity | Example 1P / 1P Model | Dimensions |
|---|---|---|
| 0.5kVA | PXe-110000.5-R | 430 × 380 × 133mm |
| 1kVA | PXe-110001-R | 430 × 380 × 133mm |
| 2kVA | PXe-110002-R | 430 × 450 × 178mm |
| 3kVA | PXe-110003-R | 430 × 450 × 178mm |
| 5kVA | PXe-110005-R | 430 × 550 × 222mm |
The phase prefix changes according to the required input and output arrangement. For example, a 5kVA three-phase input / three-phase output model is PXe-330005-R, while corresponding mixed-phase configurations use the 130 or 310 prefix.
Ordering Examples
PXe-110003-R
3kVA, single-phase input / single-phase output, 19-inch rack mount Static Frequency Converter.
A typical electrical configuration could be:
230V single-phase, 50Hz input to 115V single-phase, 400Hz output.
PXe-330005-R
5kVA, three-phase input / three-phase output, 19-inch rack mount Static Frequency Converter.
A typical 400Hz configuration could be:
400V three-phase, 50Hz input to 115/200V three-phase, 400Hz output.
The model number identifies the basic converter family, phase configuration and capacity. The complete input voltage, input frequency, output voltage, output frequency and communications requirement are confirmed as part of the quotation and configured specification.
Frequency & Voltage Options
PXe-R systems can be configured for a wide range of AC conversion duties, including 50Hz to 60Hz, 60Hz to 50Hz, 50Hz to 400Hz, 60Hz to 400Hz, voltage step-up, voltage step-down, phase conversion and combined voltage, frequency and phase conversion.
Input and output voltages are specified around the available mains supply and the electrical requirements of the connected equipment.
Phase Conversion Options
The PXe-R Series can be supplied in the following phase arrangements:
110: Single-phase input / Single-phase output
130: Single-phase input / Three-phase output
310: Three-phase input / Single-phase output
330: Three-phase input / Three-phase output
This allows the rack-mounted converter to provide phase conversion as well as voltage and frequency conversion where required by the application.
Communications Options
RS232 Communication – Standard
RS232 is supplied as the standard communications interface for connection to computers and external control equipment.
RS485 – Optional
RS485 can be specified for applications requiring longer communication distances or integration into industrial and automated control systems.
Ethernet – Optional
Ethernet communication is available for network-connected laboratory, production and remotely controlled installations.
GPIB – Optional
GPIB can be specified for integration into established laboratory instrumentation and automated test environments.
Connection Options
Input and output connections can be configured according to the rack installation and connected equipment.
Options can include hard-wired terminal connections, industrial connectors, application-specific sockets and customer-defined cable assemblies.
Specify connector type, cable length, and required current rating in the quotation.
Factory Testing & Documentation
Each PXe-R Series converter is functionally tested before shipment. Where required, the factory test procedure can incorporate application-specific voltage, frequency, and load conditions.
Additional options include customer-witnessed Factory Acceptance Testing, third-party witnessed FAT, application-specific test points, configured product specifications, factory test records, Certificates of Conformity and project-specific documentation.
Information Required for Quotation
To select and configure the correct PXe-R Series Static Frequency Converter, please provide:
Available input voltage
Input phase arrangement
Input frequency
Required output voltage
Required output phase arrangement
Required output frequency
Continuous load in VA, kVA or amps
Load type
Known starting or inrush current
Operating duty
Available rack depth and rack-space restrictions
Required communications interface
Input and output connection requirements
Any FAT, documentation or project-specific requirements
Where the load has significant start-up current, transformer inrush, motor starting demand or high crest-factor characteristics, these should be advised when requesting a quotation so that the converter can be selected against the actual application rather than steady-state power alone.
| Capacity Rack Mount Output (Other options available on request) |
0.5kVA, 1kVA, 2kVA, 3kVA, 5kVA |
| Phase Configuration | 110 – Single Phase Input / Single Phase Output 130 – Single Phase Input / Three Phase Output 310 – Three Phase Input / Single Phase Output 330 – Three Phase Input / Three Phase Output |
| Input Voltage (Select Required Voltage) |
110V, 115V, 120V, 127V, 200V, 208V, 220V, 230V, 240V, 380V, 400V, 415V, 440V, 480V Other input voltages available on request |
| Input Frequency | 50Hz or 60Hz, nominal supply frequency Application-specific input ranges confirmed for the selected model |
| Input Power Factor | ≥0.8 standard configuration Higher power-factor arrangements available where required |
| Output Voltage (Select Required Voltage) |
Typical fixed outputs include 110V, 115V, 120V, 127V, 200V, 208V, 220V, 230V, 240V, 380V, 400V, 415V and 440V AC Alternative and application-specific voltages available |
| Output Frequency | 50Hz, 60Hz or 400Hz Alternative specialist frequencies available on request |
| Voltage Accuracy | ≤ ±1% FS |
| Frequency Accuracy | ≤ ±0.1% FS |
| Total Harmonic Distortion | THD ≤3% at linear load, pure sine-wave output |
| Load Current Crest Factor Capability | 3:1 |
| Overload Capacity | 100% continuous <110% – 15 minutes <125% – 10 minutes <150% – 1 minute <200% – 5 seconds >200% – output protection operates Alternative overload characteristics available for selected applications |
| Communications | RS232 standard RS485, Ethernet or GPIB optional |
| Protection | Overcurrent, overload, overvoltage, overtemperature and short-circuit protection with alarms and status indication |
| Display & Monitoring | Digital voltage, current and frequency monitoring Additional power and status indication according to selected controller |
| Connections | Hard-wire terminals, industrial connectors, application-specific sockets or customer-defined cable assemblies |
| Enclosure | 19-inch rack-mount chassis |
| Operating Temperature | Operational: -10°C to 55°C Recommended ambient: -10°C to 45°C |
| Humidity | 10% to 90% RH, non-condensing |
| Cooling | Forced-air cooling Rack ventilation and service clearance required |
| Altitude | Up to 1800m without additional derating unless otherwise specified |
| 0.5kVA & 1kVA Dimensions | 430 × 380 × 133mm Nominal rack height: 3U |
| 2kVA & 3kVA Dimensions | 430 × 450 × 178mm Nominal rack height: 4U |
| 5kVA Dimensions | 430 × 550 × 222mm Nominal rack height: 5U |
| Factory Testing | Functional factory testing as standard Application-specific and customer or third-party witnessed FAT available |
Selected configurations provide increased short-duration peak-current capability.
Loads containing transformers, motors, large input capacitors or switched-mode power supplies should be assessed using their start-up current as well as their normal running load.
Stored operating setups are available on selected controller configurations.
This is useful for production and laboratory systems where predefined voltage and frequency conditions are used repeatedly.
Yes. The converter can be configured around both the required output voltage and frequency.
This allows equipment designed for a different regional or specialist AC supply to run on the available mains supply.
Yes. Remote communication can be provided for integration with computers, PLCs and automated test systems.
Available interfaces can include RS232, RS485, Modbus and Ethernet depending on the selected controller and required functionality.
Yes. Rack mounting is the defining mechanical format of the PXe-R Series rather than simply an optional enclosure.
Rack height, depth, cooling and weight depend on the power rating and electrical configuration.
The range can be configured for common 50Hz and 60Hz conversion duties, together with 400Hz and specialist frequencies where required.
The exact output range depends on the selected converter configuration.
Please provide the available input voltage, phase and frequency; required output voltage and frequency; continuous load; load type; expected inrush current; rack-space restrictions; operating duty; required connectors and any local or remote-control requirements.
The PXe-R Series is designed for compact 19-inch rack integration and rated up to 5kVA.
The PXe-S Series covers a much wider single-phase SFC capacity range and can be supplied in rack, bench, trolley and floor-standing formats. The R-Series is therefore the more focused choice where rack integration is a primary part of the requirement.
The PXe-R Series is a family of 19-inch rack-mounted Static Frequency Converters for installations that need AC voltage and frequency conversion integrated directly into an equipment rack, test rack, or laboratory system.
PXe-R Series configurations are available up to 5kVA.
The required rating should be selected using the continuous load together with any start-up or inrush demand.