PXe-AC-DC Series DC Output Static Converters
PXe-1-60-0000-AC-DC
PX Electronics PXe-AC-DC Series static power converters convert an available single-phase or three-phase AC supply into controlled DC output. Systems can be configured for low-voltage high-current duties, higher-voltage DC systems and industrial applications requiring regulated voltage or current.
The range uses PWM switching technology and supports constant-voltage and constant-current operation. Output voltage, current and power rating are selected around the connected equipment, test requirement and available AC input supply.
Standard configurations cover outputs from low-voltage high-current supplies through to DC voltages of 1200V and higher-power systems up to 480kW. A defined example is the PXe-AC-DC-6-5000, providing adjustable output from 0 to 6V DC and 0 to 5000A, with a 30kW rating.
Technical Highlights for AC-to-DC Power Conversion
Regulated DC Power Control
Converts 50Hz or 60Hz AC input into controlled DC output, with constant-voltage and constant-current operating modes to suit changing load conditions.
Low-Voltage, High-Current Capability
Configurations are available for current injection, busbar testing, current sensor testing, contactors, DC motors and other applications requiring substantial current at relatively low voltage.
High-Voltage & High-Power Configurations
Output voltages are available up to 1200V DC, with system ratings extending from compact lower-power units to engineered AC-to-DC converters up to 480kW.
Adjustable Limits & Built-In Protection
Programmable voltage and current limits help protect both the converter and connected equipment, supported by overvoltage, overcurrent, overtemperature and short-circuit protection.
Local Monitoring & Remote Integration
Digital indication provides voltage, current, power, and operating information depending on configuration, with optional RS232, RS485, and Modbus communications for PLC, computer, and automated-system integration.
Product Information
PXe-AC-DC Series Configurations
PXe-AC-DC Series converters are configured around the available AC input, required DC voltage and current, load type, duty cycle and control requirements.
Single-phase input is available on selected lower-power models. Larger systems generally use a three-phase input to reduce the current carried by each incoming phase.
Available Configurations
| Parameter | Available Configuration |
|---|---|
| Input Phase | Single-phase on selected lower-power models or three-phase four-wire for higher ratings |
| Input Voltage | Typically 220V single-phase or 380/400V three-phase, with ±10% input tolerance |
| Input Frequency | 50Hz or 60Hz |
| DC Output Voltage | Configured to suit the application, including low-voltage outputs and standard ranges up to 1200V DC |
| DC Output Current | Selected according to the required continuous current, peak current and duty cycle |
| Power Rating | Lower-power rack systems through to engineered floor-standing systems rated up to 480kW |
| Operating Modes | Constant voltage and constant current |
| Control | Front-panel operation with optional RS232, RS485 or Modbus communication |
| Construction | Rack-mounted or floor-standing, depending on voltage, current and power rating |
| Cooling | Forced-air cooling using exhaust fans |
Popular Configurations
The configurations below show representative combinations from the wider PXe-AC-DC Series. Alternative voltage and current ratings can be supplied following technical review.
| Model | DC Output | Power | Typical Application |
|---|---|---|---|
| PXe-AC-DC-30-100 | 30V / 100A | 3kW | Component testing, DC motors and lower-current industrial loads |
| PXe-AC-DC-30-200 | 30V / 200A | 6kW | Current sensor, contactor and cable testing |
| PXe-AC-DC-30-500 | 30V / 500A | 15kW | High-current component testing and industrial DC systems |
| PXe-AC-DC-30-1000 | 30V / 1000A | 30kW | Busbar, cable and high-current assembly testing |
| PXe-AC-DC-60-100 | 60V / 100A | 6kW | DC machinery, control equipment and development systems |
| PXe-AC-DC-60-250 | 60V / 250A | 15kW | Industrial testing and higher-current DC loads |
| PXe-AC-DC-100-150 | 100V / 150A | 15kW | Industrial controls, DC motors and power electronics |
| PXe-AC-DC-150-200 | 150V / 200A | 30kW | Higher-voltage machinery and DC system validation |
| PXe-AC-DC-300-100 | 300V / 100A | 30kW | Industrial DC buses and high-voltage equipment testing |
| PXe-AC-DC-600-100 | 600V / 100A | 60kW | High-voltage DC systems and power electronics development |
| PXe-AC-DC-1200-100 | 1200V / 100A | 120kW | High-voltage industrial and specialist DC installations |
| PXe-AC-DC-6-5000 | 0 to 6V / 0 to 5000A | 30kW | Very-high-current injection, busbar, shunt and sensor testing |
The listed model format uses the DC output voltage followed by the maximum output current. Availability, dimensions and input requirements are confirmed for each configuration.
High-Current Installation Considerations
For low-voltage high-current systems, the complete output circuit must be considered. Cable resistance, busbar resistance, contact resistance and connection quality can materially reduce the voltage available at the load.
PX will normally review:
- Required voltage at the equipment
- Continuous and peak current
- Output cable length
- Cable or busbar cross-section
- Permitted voltage drop
- Terminal and connector arrangement
- Duty cycle
- Cooling requirement
- Load isolation
- Protective bonding and earthing
Remote sensing may be considered where accurate voltage is required at the load rather than only at the converter terminals, subject to the selected design.
Order Codes:
A product order code can be derived from the main ordering information using the structure below:
Generic order code is based on this format: PXe-1-28-0003-AC-DC, indicating 1ph-input 28Vdc-output and 3kVA
For example a 1 phase in 50Hz, 28Vdc phase out, 3kVA, = PXe-1-28-0003
PXe-1-28-0000-AC-DC-[INPUT]-[OUTPUT1]-[OUTPUT2]-[RATING]-[ENCLOSURE]-[CONTROL]
PXe-1-28-0003-AC-DC-[1P230V50]-[28VDC]-[3KVA]-[IP22]-[RS232]
This would represent:
(PXE-1-28-0003-AC-DC) – PX Electronics AC-DC Converter
(1P230V50) – 1 phase, 230VL-L, 50Hz input
(28VDC) – 28Vdc output
(3KVA) – 3kVA rating
(IP22) – IP22 enclosure
(RS232) – Control
For a manually controlled standard enclosure version, the part number may look like this:
PXe-1-28-0003-AC-DC-1P230V50-28Vdc-3kVA-IP22-RS232
| Model | Capacity | Rated Current | Input | Output | Dimensions | Weight |
|---|---|---|---|---|---|---|
| PXe-1-28-0003-AC-DC | 3kW | 0-100A Adjustable | 220V ±10% | 1 Phase | 50Hz | 28Vdc (0-30Vdc adjustable) | 482x450x88mm | 13kg |
| PXe-1-24-0005-AC-DC | 5kW | 0-208A adjustable | 230V ±10% | 1 Phase | 50Hz | 24Vdc (0-30Vdc adjustable) | 482x450x222mm | 23kg |
Available Options
Alternative DC Output Ratings
Voltage and current can be configured around the required operating point, subject to the available input supply and total output power.
Programmable Voltage and Current Control
Selected systems can provide adjustable output settings and programmable voltage or current limits.
RS232, RS485 and Modbus
Optional communications allow connection to computers, PLCs and automated test equipment.
Stored Operating Settings
Selected models can store voltage and current settings for repeatable test operation. The number of available memory positions is model-dependent.
High-Current Busbar Output
Bolted busbars and heavy-duty terminations can be supplied for high-current installations.
Remote Voltage Sensing
Remote sensing can be considered where output-circuit voltage drop needs to be compensated at the load.
Rack-Mount Construction
Lower-power units can be supplied in rack-mounted formats where the voltage, current and cooling requirements allow.
Floor-Standing Cabinet
Higher-power and high-current systems are supplied in ventilated floor-standing cabinets.
Custom Cables and Connections
Output cables, busbars, terminal covers, isolators and customer-specific connection assemblies can be discussed.
Factory Acceptance Testing
FAT can include output voltage and current checks, regulation, protection operation, communication tests and customer-agreed load points.
Customer or Third-Party Witness Testing
Formal witness testing can be arranged where required for project acceptance.
PXe-AC-DC Series Technical Specification
The values below represent the standard series specification. Model-specific performance is confirmed in the final technical proposal.
| Specification | PXe-AC-DC Series |
|---|---|
| Conversion Technology | PWM switching |
| Power Range | Lower-power systems through to 480kW |
| Input Phase | Single-phase or three-phase four-wire, depending on rating |
| Input Voltage | 220V AC or 380/400V AC ±10%, depending on configuration |
| Input Frequency | 50Hz or 60Hz, ±10% |
| DC Output Voltage | Application-specific; standard ranges include 30V, 60V, 100V, 150V, 300V, 600V, 900V and 1200V DC |
| DC Output Current | Selected according to output voltage and power rating; custom high-current configurations available |
| Ripple | 1% full scale |
| Load Regulation | ±1% full scale |
| Voltage Setting Range | 10% to 100% rated voltage in constant-voltage mode |
| Current Setting Range | 10% to 100% rated current in constant-current mode |
| Setting Accuracy | Voltage ±1%; current ±1% |
| Measurement Accuracy | Voltage, current and power: 0.5% full scale + 5 digits |
| Voltage Resolution | 0.1V below 1000V; 1V at 1000V and above |
| Current Resolution | Model-dependent according to rated current |
| Power Resolution | 0.1W |
| Display | Voltage, current, power and time |
| Stored Settings | Voltage and current memories available; quantity depends on selected controller |
| Current Limit | Adjustable from zero to maximum rated current |
| Voltage Limit | Adjustable from zero to maximum rated voltage |
| Protection | Overvoltage, overcurrent, overtemperature and short-circuit protection |
| Cooling | Forced-air cooling using exhaust fans |
| Operating Environment | 0°C to 40°C; 20% to 80% RH, non-condensing |
Yes. The range includes high-current configurations.
The PXe-AC-DC-6-5000 example provides up to 5000A at an adjustable output of up to 6V DC.
Yes. Optional RS232, RS485 and Modbus communication can be provided for remote operation and automated test integration.
The required commands and readback values should be confirmed before order.
Yes. Adjustable-output configurations are available with constant-voltage and constant-current operation.
The standard adjustment range is typically 10% to 100% of the selected rated voltage or current.
Potentially, but the charging requirements must be reviewed carefully.
Battery chemistry, maximum charging voltage, current profile, temperature monitoring, isolation and charge termination must all be defined. A general industrial DC converter should not automatically be treated as a complete battery charger.
PX Electronics will require the available AC input, required DC voltage and current, continuous power, load type, duty cycle, ripple and regulation requirements, control method, communications, output-cable arrangement and required test documentation.
An AC-to-DC static converter takes an AC mains input and produces regulated DC voltage and current.
Unlike an AC-output Static Frequency Converter, the DC output has no operating frequency.
In constant-voltage mode, the converter maintains the selected voltage while current changes with the load.
In constant-current mode, the converter maintains the selected current while output voltage changes within the available range.
The series is used for industrial DC power, product testing, current injection, DC motor testing, component ageing, high-current testing and specialist low-voltage or high-voltage DC applications.
Protection includes overvoltage, overcurrent, overtemperature and short-circuit protection.
Adjustable voltage and current limits can also be used to restrict the permitted output.