Capacity
|
Single Phase output |
kVA Ratings: 0.5kVA, 1kVA, 3kVA, 5kVA, 10kVA, 15kVA, 20kVA, 30kVA, 50kVA, 60kVA, 75kVA, 100kVA, 150kVA, 200kVA |
Three Phase output versions |
kVA Ratings: 1kVA, 3kVA, 6kVA, 9kVA, 15kVA, 20kVA, 30kVA, 45kVA, 60kVA, 100kVA, 150kVA, 200kVA, 300kVA, 400kVA, 500kVA~2000kVA (Select One kVA) |
Input
|
Single phase (Select One Individual Voltage) |
110Vac ±10%, 115Vac ±10%, 120Vac ±10%, 127Vac ±10%, 220Vac ±10%, 230Vac ±10% |
Three phase (Select One Individual Voltage) |
115-127 (L-N) / 200-220V (L-L) ±10%,220-240 (L-N) / 380-415V (L-L) ±10%, 3 Phase 4Wire, 440V (L-L) ±10%, 480V (L-L) ±5%, 3Phase 3 Wire |
Frequency |
50Hz/60Hz ±5%, 400Hz (Optional) |
Power factor |
≥ 0.8 (standard type)≥ 0.9 (optional 12 pulse type) |
Output
|
Single phase (Select One Individual Voltage) |
Fixed: 110V, 115v, 120V, 127V, 220V, 230V, 240V, Adjustable: 0~150Vac/0~300Vac |
Three phase (Select One Individual Voltage) |
Fixed: 115/200V (L-N/L-L), 120/208V (L-N/L-L), 127/220V (L-N/L-L), 220/380V( L-N/L-L), 230/400V (L-N/L-L), 240/415V (L-N/L-L), 254/440V (L-N/L-L), 277/480V (L-N/L-L), 3 Phase 4 Wire, Adjustable: 0~260V (L-N)/0~520V (L-L), 3 Phase 4 Wire |
Frequency |
Fixed: 50Hz, 60Hz, 100Hz, 200Hz, 45-200Hz (adjustable) Optional: 400Hz/40Hz~500Hz (adjustable), 16.67Hz, 25Hz, 50Hz, 60Hz, 400-1000Hz |
Voltage Accuracy |
≤ ±1% FS (Full Scale) |
Frequency Accuracy |
≤ ±0.1% FS (Full Scale) |
Total harmonic distortion |
THD ≤ 3% @ linear load, pure sine wave output |
Crest Factor (pk/rms) |
3:1 |
Overload |
100% for continuous, 101-200% shut down in 200mS |
Interface |
RS232C/RS485/Ethernet/GPIB/Labview Drivers (Optional) |
Protection |
Over current, over-load, over-voltage, over-temp, short circuit, alarm and indicators |
Enclosure IP Ratings |
IP22 (Standard), IP32, IP54 (Optional) as per requirement |
LED/LCD display |
- Digital frequency meter
- Digital voltage meter
- Digital current meter
- Digital power/PF meter
|
Connectors |
Hard-wire terminals, EN60309, MIL-STD, Or client choice |
Operating conditions
|
Temperature |
Operation: -10℃~55℃. Ambient: -10℃~45℃ |
Noise |
≤ 65dB at 1 meter
EN 5022, IEC1000-4 |
Humidity |
10~90% non-condensing |
Cooling |
Variable speed turbine, air intake in base, exhaust at rear |
Altitude |
≤ 1800m |
Castors or Feet |
0.5-3kVA have rubber feet and lifting handles, 4kVA+ have castors with front brakes. A/Vs or feet optional |
CE |
CE Marked |
Reliability and Efficiency
|
Mean Time Between Failure (MTBF) |
50,000Hrs |
Mean Time To Restore (MTTR) |
< 30 min |
Overall efficiency |
≥ 85% |
Standards
|
GB50054-95, GB 50150-1991, GB 50150-2006, GB 50171-1992, GB/T 16935.5-2008, GB/T16935.4-2011 |
EN IEC61000-3-2, EN 61000-3-3, EN55032, EN55035, MIL-STD-1399, MIL-STD-461, MIL-STD-704, STANAG 1008 |
For more information and support, please feel free to contact us |