PXe-PA920 Multi Channel High Accuracy Three Phase Power Analyser

Introducing the new Ultra High Accuracy PXe-PA920 Precision Multi Channel Harmonic Power Analyser, the newest addition to PXe’s family of Power Analyser products.

The new PXe-PA920 is the most powerful, accurate and flexible power analyser available on the market today. Available with 0.024% power accuracy. These new products provide faster sampling rates, bandwidth performance and greater harmonic frequency, yet are still easy-to-use and affordable.

The PXe-PA920 power analysers offer expanded power analysis options. Offering ultra high 0.024% power accuracy for all channels and improved voltage and current self-heating adders over those of other power analysers. In addition, the PA920 provides easy channel selection for the user while offering 100 full precision readings per second and measurement bandwidths sufficient to handle 5 MHz waveforms.

When You Need Maximum Performance & Accuracy Choose PXe’s PA920 Precision Harmonic Power Analyser.

– Ultra High Power Accuracy of 0.024% For All Channels
– Improved Voltage and Current Self-Heating Adders
– Faster Sampling Rates & Bandwidth Performance
– Greater Harmonic Frequencies

You may also like the other models in the PXe-PA9xx series the PXe-PA900 and PXe-PA910:

PXe-910 High Accuracy (0.045%) Precision Multi-Channel Power Analyzer

PXe-900 Three phase Power Analyzer

PXe-PA9xx Flexible multi channel Power Analyser

Description

Industry’s Most Accurate Power Analyser – PXe’s 920 Series power analysers are the industry’s most powerful and accurate power analyzer.  The PXe-920 offers 0.024% power accuracy, the fastest available on the market today. All PXe power analysers are easy to use with a full colour touchscreen enabling users to quickly and easily setup configurations, custom screens and interface commands.

Maximise Flexibility – The PXe-920 power analysers offer expanded power analysis options. The PXe-920 offers 0.024% power for all channels and improved voltage and current self-heating adders over those of other power analysers. In addition, the PXe-920 provides easy channel selection for the user while offering 100 full precision readings per second and measurement bandwidths sufficient to handle 5 MHz waveforms.

Maximum Results – For tackling tough power factor, low phase angle and high crest factor loads, the PXe-920 power analyzers are unbeatable. Offering full performance for crest factors as high as 100:1, the PA9xx series provides superior power measurement capabilities for the toughest power measurement applications.

Maximum Performance in a Variety of Applications – Design engineers are under constant pressure to increase efficiency and reduce excess product power consumption down to the last mW. Challenging programs like LED and HID lighting, solar panel energy output, efficiency testing on inverters and PWM motor drive systems on electric vehicles—all require fast, precise, reliable power measurement. The unequalled performance of the PXe-910/920 gives you the competitive advantage—the ability to accurately capture the waveforms and power data you need to squeeze the last drop of extra energy out of your project.

Modular Design = Maximum Flexibility – The PXe-920 Series Power Analysers are available in both pre-configured models or can be purchased in a modular package to provide the performance you need at a price that meets your budget. A single PA920 offers 8 available channel combinations to meet your power analysis needs.

PXe-920 Only Channel Cards for use with PXe-920 Mainframe (0.024% Accuracy)
UT Channel Card – Ultra-Precision Dual Shunt (1, 30A) Channel Card
UX Channel Card – Ultra-Precision External Current Transducer Input Channel Card
BT Channel Card – High Bandwidth Dual Shunt (1, 30A) Channel Card
BX Channel Card – High Bandwidth External Current Transducer Channel Card
KT Channel Card – Kilovolt (1.6kVrms Continuous) Dual Shunt (1, 30A) Channel Card
KX Channel Card – Kilovolt (1.6kVrms Continuous) External Current Transducer Input Channel Card
MT Channel Card – Motor Transducer Channel Card (Slot 4 only)

Harmonics Screen

Harmonics Screen

To meet advanced power harmonics requirements, the PXe-920 displays up to 500 harmonics even at aviation power frequencies. The chart can be set to show linear, relative linear, logarithmic or relative logarithmic amplitudes. Additionally, 8 harmonics can be selected for numeric display of amplitude and phase by touching the harmonic bar of interest. The user may also import harmonic limits, which when enabled will show out of tolerance harmonics in red above the limit line.

Power Data Screen

Power Screen

The power data screen, available with one touch, displays V, A, W, VA, VAR and PF data for any selected channel or group of channels known as a Virtual Power Analyzer™ (VPA). Up to three different VPAs can exist in in a single PA920. In addition to the primary data, peak readings, phase, CF and other parameters are also available. Integrated data results (WHr) can also be controlled and viewed from the power data screen. For users with unique data requirements, custom data screens can be built with a spreadsheet application and downloaded to the PA920 via interface or USB drive.

Scope View

Scope Screen

Scope view offers waveform acquisition and analysis similar to a digital scope. Up to 6 signals can be displayed, each having user selectable scaling, offset and colour. Timebase, trigger and trigger position are all user selectable. However, with amplitude accuracies as high as 0.03% – you are unlikely to find any other scope with this high level of precision.

Cycle View

Cycle View Screen

The cycle view represents a single cycle of the voltage and or current periodic waveforms. The above waveforms represent a full 10V square wave in blue and a 50:1 zoomed in view in red. Since the user sets amplitude and scaling – the result is an almost unlimited ability to amplitude zoom to expose fine detail. The sampling is forced to be asynchronous to higher order harmonics which leads to an effective sampling rate of 384MSPS.

Vector Screen

Vector Screen

A polar chart graphically displays the fundamental voltage and current vectors for the selected channel or VPA. For multi-phase VPAs, the inter-phase voltages and non-measured neutral phase vectors are displayed. The user may enable the display of and select the colour of each vector up to a maximum of 10.

History Screen

History Screen

The PXe-920 automatically maintains a continuous historical record of all non-harmonic measurement results and selected harmonics. Up to four user selectable parameters can be graphically displayed using the HISTORY screen. The user can display the entire recorded period up to 397 days or zoom in as far as 1/64th of the total span. This provides an almost unlimited ability to amplitude zoom and includes a cursor which may be moved throughout the period with a touch of the screen.

Standby Power Screen

Standby Power Screen

The PxE-920 features built in standby power testing in accordance to EN50564:2011 (replaces IEC62301) which can be started with the press of a finger from the STBY POWER screen. All information is neatly organised onto a single screen for easy viewing and can just as easily be saved as an image file into a connected USB drive to add into any report. Various measurement methods laid out in EN50564:2011, minimum test time, and data-logging capability are all selectable. The PA920 also has the ability to perform standby power measurements independently in each configured VPA.

Product Features

  • Highest Accuracy Power Analyzer Available On The Market Today
  • Highest Precision Accuracy – 0.024%
  • Up to 500 Harmonics at 400Hz, meets Airbus avionics harmonics measurement criteria. Bar graph also features fingertip selectable numeric amplitude and phase data
  • Large, Hi-Resolution Color Display shows all the data you want with an easy-to-use touchscreen user interface to get you up and testing in no time
  • Modular design lets you choose up to 4 Power Measurement Channel Cards in any combination of 3 different Channel Card types
  • Built-in Data Logger – Logs up to 16 selectable data results to USB thumbdrive or internal data storage. Intervals from 10mS to 100 hours with optional time/date stamps
  • Power Data Screen – displays V, A, W, VA, VAR and PF data for any selected channel or group of channels
  • Custom Power Data Screens – lets you choose the color, font size, location and data you want displayed
  • With selectable time base and triggering – Scope View, acts as a digital scope to capture events such as in-rush current
  • Cycle View – Represents a single cycle of the voltage and current periodic waveforms sampled over many cycles within a measurement period
  • Vector Screen – Displays up to 10 fundamental voltage & current vectors
  • History Screen – Like a DVR, the PA920 automatically maintains a continuous historical recording of measurement data. Any data from this record may be viewed or downloaded. Pause, clear & restart functionality is available from the HISTORY screen or via interface
  • Standby Power Screen – Test in accordance to EN50564:2011 with an easy to set up, easier to use built in application. One screen holds all of your necessary data.
  • Effective Sampling Rate – for analysis of periodic signals within a measurement period is 384MSPS
  • Measurement Resolution – 22 bit for S & W type Channel Cards, 24 bit for A type
  • Up to 3 Different Virtual Power Analyzers™ (VPAs) may be configured for three phase measurements or input/output efficiency tests – so there is no need to interconnect separate units in order to make synchronous or non-synchronous group power measurements
  • VPA Efficiency Grouping – Available data includes: Power totals for IN, MIDDLE and OUT efficiency groups, the power loss between any pair of groups, and the percentage efficiency between any pair of groups
  • VPA Multi-Channel Wiring – Each VPA may be configured as 2ø3w (2 ch), 3ø3w (2 ch), 3ø3w (3 ch), 3ø4w (3 ch)
  • Connectivity – Ethernet, High Speed Serial and USB (client) control interfaces
  • Optional Multi-Unit (Option MU) connection available to combine multiple PXe-920 units to enable you to make measurements with up to thousands of channels
  • Front Panel USB Drive Interface – Permits data logging to a file, ‘screen shot’ capture, easy import and export of: display and measurement configurations & custom data screen definitions
  • Available MT type Channel Card for motor torque & speed inputs
  • CE mark certified to EN61010
  • 2 Year Parts & Labour Warranty, 2 Year Accuracy Specs and calibration cycle

Accuracy specifications are valid for a period of two years after calibration in normal use. Consult operating manual for full specifications.

Voltage Input Capability and Characteristics

Specification V Channel Type K Channel Type B Channel Type U Channel Type
Voltage Input Burden 1.201MΩ ± 3kΩ 2MΩ ± 5kΩ 801.5kΩ ± 2kΩ 1.201MΩ ± 3kΩ
Maximum Measurable Voltage (pk, de or rms) 2kV 3.3kV 1350V 2kV
Max. Specified Continuous Voltage (within maximum measurable peak) >PA910
PA920
1000VRMS Not Available Not Available Not Available
Not Available 1625VRMS 800VRMS 1250VRMS
No Damage Voltage < 1ms
< 100ms
< 5s
<3kVRMS and VPK <4kVRMS and VPK <3kVRMS and VPK <3kVRMS and VPK
<2kVRMS <2.5kVRMS <2kVRMS <2kVRMS
<1.5kVRMS <2kVRMS <1.5kVRMS <1.5kVRMS
Mains Safety Rating 10DOV/CAT II, 600V/CAT III, 300V/CAT IV 600V/CATII or III 300V/CAT IV 1000V/CAT II, 600V/CAT III, 300V/CAT IV
Transient Isolation Voltage (to ground) >4.5kVpk
Voltage Accuracy (DC, 20Hz-1kHz) ± Self-Heating Adder >PA910
PA920
± 0.03%±0.02% per kV2 Not Available Not Available Not Available
Not Available ± 0.03%±0.06% per kV2 ± 0.03%±0.015% per kV2 ± 0.015%±0.0075% per kV2
DC Voltage Floor ±0.9mV ±1.35mV ±1.8mV ±0.9mV
AC Voltage Floor (10kHz BW) 450µV + 1OOµV/vrdg 750µV + 2OOµV/vrdg 300µV + 75µV/vrdg 450µV + 100µV/vrdg
3dB Voltage Bandwidth (tvpical) 2MHZ 850kHZ 4.5MHZ 2MHZ
Maximum Harmonic Freauency < 590kHZ and <500 harmonics
Effective Sampling 24bits @ 192MSPS
Physical Sampling 6bits+ 18bits @ > 1.2MSPS combined

Current Input Capability and Characteristics

Specification T Current Option X Current Option
HI Range LO Range HI Range LO Range
Current Input Burden 8mΩ nominal 505mΩ nominal 153kΩ ± 0.5kΩ 100.5kΩ ± 0.3kΩ
Maximum Measurable Current (pk, de or rms) 150A 1.5A 15V 0.6V
Specified Continuous Current (within measurable peak) PA910
PA920
30ARMS 1.25ARMS 12VRMS 0.5VRMS
32ARMS
No Damage Current <8ms
<40ms
<1s
<200ARMS and <300APK <150ARMS and <200APK < lkVRMs and VPK (fuse protected above 18V)
<75ARMS <40ARMS
<50ARMS <5ARMS
Mains Safety Rating (Isolation) 1000V/CAT II, 600V/CAT III, 300V /CAT IV
Transient Isolation Voltage (to ground) >4.5kVpk
Current Accuracy (DC, 2 OHz-lkHz) ± Self-Heating Adder UT or UX
Other
±0.018% ± 0.000025% Per A2 ±0.018%
± 0.03%± 0.00005% per A2 ± 0.03%
DC Current Floor BT or BX
Other
±438µA ±3.25µA ±126µA ±6.15µA
±188µA ±1.25µA ±46µA ±5.15µA
AC Current Floor (10kHz BW) 38µA + 1.5µA/Ardg 0.25µA + 0.1nA/Ardg 6µA + 35nV/Vrdg 0.15µA + 0.02nV/Vrdg
3dB Current Bandwidth (typical) BT or BX
Other
5MHZ 2.5MHZ
2MHZ
Maximum Harmonic Frequency < 590kHz and <500 harmonics
Effective Sampling 24bits @ 192MSPS
Physical Sampling 6bits+ 18bits@ > 1.2MSPS combined

Power (W) Input Capability and Characteristics

Specification V Channel Type K Channel Type B Channel Type U Channel Type
Power Accuracy(DC, 20Hz-1kHz) PA910
PA920
±0.045% Not Available Not Available Not Available
Not Available ±0.045% ±0.045% ±0.024%
Self-Heating Adder ± (V and A self-heating)
DC Power Floor (Applvto DC Only) (Vrdg*DC current floor) ± (Ardg*DC voltage floor) ± (DC voltage floor*DC current floor)
Phase Floor ± 0.005oper kHz ± 0.003oper kHz ± 0.005oper kHz
Note: Specifications subject to change.

Dimensional

Nominal Dimensions 137mmH x 248mmW x 284mmD ( 5.4″ x 9.75″ x 11.2″) with feet not extended
Nominal Weight 3.2kg (71b) net, 5kg (111b) shipping

Environmental

Storage Environment -20 to 75C (-4 to 167F) (non-condensing)
Operating Environment 0 to 40C (32 to 104F), <85% RH (non-condensing), Pollution Degree 2
Operating Altitude 0 to 2000m (6560ft) ASL

Power Supply

Line Power Installation Category 11; 85-264Vrms, 45 to 65Hz, 40VA max. Internally fused with a non-user serviceable fuse

Interfaces

LAN (Ethernet), Serial (RS232), USB (Client) and USB (Host – Front Panel) for mass data storage

Display

7″ 800x480px 18bpp color LCD with resistive touch panel.
Star Icon

Quality

We are committed to providing products that meet international quality requirements. PX Electronic certifies that all products meet or exceed their published specification, European & USA safety requirements.

Find Out More
box icon

Shipping

At PX Electronics all of our products are available to ship worldwide.

Use the link below to view our product range.

View Now
question mark icon

FAQ’s

If you can’t find the answer you’re looking for?

Dont worry we have shared some of our most frequently asked questions to help you.

Read more